AAS - Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type)
HomeStore

AAS - Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type)

AAS - Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type)

$100.00
AAS - Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type)
$100.00

The Story

AAS - Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type)

AAS – Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type) is a high-precision analytical system designed for accurate metal analysis. It delivers strong selectivity, broad analytical applicability, high sensitivity, simple operation, cost-efficient performance, and reliable accuracy, making it suitable for demanding laboratory environments.

This instrument is widely applied in fields such as geology, mining, metallurgy, agriculture, forestry, hydrology, environmental monitoring, petrochemical processing, food and pharmaceutical safety, and third-party testing laboratories.

The flame system is built with high-stability flow control technology to ensure precise and automated gas regulation during operation. A durable gas-liquid separation unit, gas filtration system, and supporting components help maintain stable performance even in high humidity conditions or areas with limited gas supply.

Integrated safety interlocking mechanisms and intelligent alert functions provide automatic shutdown and alarm responses in case of operational irregularities, enhancing overall protection during use.

Its modular design and well-structured circuit architecture allow convenient maintenance, enabling fast component replacement and efficient servicing without complex procedures.

The system also supports expandable analytical techniques such as the hydride generation method, flame emission technique, and high-temperature flame analysis. Additional accessories, including an automatic flame sampler, further enhance workflow efficiency and analytical flexibility.

Performance Index

  • Wavelength Range: 170 nm – 900 nm

  • Wavelength Accuracy: ≤ ±0.10 nm

  • Wavelength Repeatability: ≤ 0.05 nm

  • Baseline Stability:

    • Drift ≤ 0.002 Abs, noise ≤ 0.001 Abs (stable 30 min)

    • Drift ≤ 0.002 Abs, noise ≤ 0.001 Abs (dynamic 15 min)

  • Resolution Performance: Spectral bandwidth deviation ≤ 0.02 nm; manganese double-line peak-to-valley ratio ≤ 25%

  • Flame Method for Copper:

    • Detection limit ≤ 0.002 μg/mL

    • Characteristic concentration ≤ 0.025 μg/mL per 1%

    • Precision ≤ 0.3%

  • Background Correction Capability:

    • Deuterium lamp method up to 1.0 Abs with background ≥ 90×

    • Self-absorption correction up to 2.0 Abs with background ≥ 90×

Light Source System

  • 8-Lamp Configuration: High-performance turret design with automatic rotation, switching, and optical alignment

  • Simultaneous Operation: Supports up to 8 lamps running together for preheating and improved analytical throughput

  • Memory Function: Individual lamp parameters can be edited and stored without programming requirements

Optical System

  • Monochromator: Czerny-Turner optical layout with 277 mm focal length

  • Diffraction Grating: 1800 grooves/mm with blaze wavelength at 250 nm

  • Spectral Bandwidth Control: Adjustable settings of 0.1 nm, 0.2 nm, 0.4 nm, 0.8 nm, and 1.6 nm with automatic switching

  • Detector: High-sensitivity photomultiplier tube with wide spectral response

  • Intelligent Automation: Automatic peak detection, scanning, energy calibration, slit adjustment, and wavelength optimization without manual reset

Flame System

  • Burner Head: 10 cm titanium burner optimized for air-acetylene flame, including emission mode support

  • Spray Chamber: PPS material construction offering corrosion resistance, heat tolerance, flame resistance, hydrophobic properties, and mechanical strength

  • Adjustable Burner Control: Flexible vertical and horizontal positioning with rotatable angle adjustment

  • Automated Ignition System: Mass flow-controlled fuel regulation with automatic ignition and shutdown functions

  • Flame Data Interface: Real-time readable detection output via foot pedal operation

Software Workstation

  • One-Touch Operation: Simplified workflow for instrument optimization and multi-sample analysis

  • Repeat Testing: 1–99 cycles with automatic calculation of mean, standard deviation, and RSD

  • Intelligent Processing: Automatic curve fitting, concentration calculation, re-slope adjustment, and standard addition method support

  • Reporting Tools: Data export and printing available in Word, Excel, and other formats

Safety Protection System

  • Dual Safety Architecture: Combined hardware and software alarm system for enhanced operational safety

  • Flame Safety Controls: Automatic gas shutoff, shutdown sequence, and alarm activation during abnormal pressure, ignition failure, leakage, or unstable flow conditions

  • Independent Protection Modules: Emergency flame shutdown switch and high-current protection for furnace safety

Optional Functional Configurations

Flame Automatic Sampler (Optional)

  • Independent sampling system designed for flame analysis without disturbing furnace setup

  • Quick-release sample tray system for fast handling of standard and sample containers

  • Capacity for 70-position trays with ≥20 mL per cup using universal consumables

  • Automatic positioning, alignment correction, and high-flow multi-stage cleaning system

Oxygen-Enriched High-Temperature Flame (Optional)

Enables high-temperature element analysis such as aluminum, barium, molybdenum, and vanadium while avoiding hazardous oxidizing gases

Wide-Slit Combustion Head (Optional)

Supports complex sample stability with adjustable nebulizer for improved analytical consistency

Hydride Generation System (Optional)

Extends analytical capability for additional elements using hydride vapor techniques

Audit Trail Software (Optional)

Includes electronic signatures, user access control, and full process traceability for compliance with audit requirements

AAS - Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type) Dimensions and Weight

  • Main Unit: 1020mm×530mm×500mm(L×W×H), 85kg
  • Flame automatic sampler: 440mm×290mm×440mm(L×W×H), 14kg.

Description

AAS - Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type)

AAS – Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type) is a high-precision analytical system designed for accurate metal analysis. It delivers strong selectivity, broad analytical applicability, high sensitivity, simple operation, cost-efficient performance, and reliable accuracy, making it suitable for demanding laboratory environments.

This instrument is widely applied in fields such as geology, mining, metallurgy, agriculture, forestry, hydrology, environmental monitoring, petrochemical processing, food and pharmaceutical safety, and third-party testing laboratories.

The flame system is built with high-stability flow control technology to ensure precise and automated gas regulation during operation. A durable gas-liquid separation unit, gas filtration system, and supporting components help maintain stable performance even in high humidity conditions or areas with limited gas supply.

Integrated safety interlocking mechanisms and intelligent alert functions provide automatic shutdown and alarm responses in case of operational irregularities, enhancing overall protection during use.

Its modular design and well-structured circuit architecture allow convenient maintenance, enabling fast component replacement and efficient servicing without complex procedures.

The system also supports expandable analytical techniques such as the hydride generation method, flame emission technique, and high-temperature flame analysis. Additional accessories, including an automatic flame sampler, further enhance workflow efficiency and analytical flexibility.

Performance Index

  • Wavelength Range: 170 nm – 900 nm

  • Wavelength Accuracy: ≤ ±0.10 nm

  • Wavelength Repeatability: ≤ 0.05 nm

  • Baseline Stability:

    • Drift ≤ 0.002 Abs, noise ≤ 0.001 Abs (stable 30 min)

    • Drift ≤ 0.002 Abs, noise ≤ 0.001 Abs (dynamic 15 min)

  • Resolution Performance: Spectral bandwidth deviation ≤ 0.02 nm; manganese double-line peak-to-valley ratio ≤ 25%

  • Flame Method for Copper:

    • Detection limit ≤ 0.002 μg/mL

    • Characteristic concentration ≤ 0.025 μg/mL per 1%

    • Precision ≤ 0.3%

  • Background Correction Capability:

    • Deuterium lamp method up to 1.0 Abs with background ≥ 90×

    • Self-absorption correction up to 2.0 Abs with background ≥ 90×

Light Source System

  • 8-Lamp Configuration: High-performance turret design with automatic rotation, switching, and optical alignment

  • Simultaneous Operation: Supports up to 8 lamps running together for preheating and improved analytical throughput

  • Memory Function: Individual lamp parameters can be edited and stored without programming requirements

Optical System

  • Monochromator: Czerny-Turner optical layout with 277 mm focal length

  • Diffraction Grating: 1800 grooves/mm with blaze wavelength at 250 nm

  • Spectral Bandwidth Control: Adjustable settings of 0.1 nm, 0.2 nm, 0.4 nm, 0.8 nm, and 1.6 nm with automatic switching

  • Detector: High-sensitivity photomultiplier tube with wide spectral response

  • Intelligent Automation: Automatic peak detection, scanning, energy calibration, slit adjustment, and wavelength optimization without manual reset

Flame System

  • Burner Head: 10 cm titanium burner optimized for air-acetylene flame, including emission mode support

  • Spray Chamber: PPS material construction offering corrosion resistance, heat tolerance, flame resistance, hydrophobic properties, and mechanical strength

  • Adjustable Burner Control: Flexible vertical and horizontal positioning with rotatable angle adjustment

  • Automated Ignition System: Mass flow-controlled fuel regulation with automatic ignition and shutdown functions

  • Flame Data Interface: Real-time readable detection output via foot pedal operation

Software Workstation

  • One-Touch Operation: Simplified workflow for instrument optimization and multi-sample analysis

  • Repeat Testing: 1–99 cycles with automatic calculation of mean, standard deviation, and RSD

  • Intelligent Processing: Automatic curve fitting, concentration calculation, re-slope adjustment, and standard addition method support

  • Reporting Tools: Data export and printing available in Word, Excel, and other formats

Safety Protection System

  • Dual Safety Architecture: Combined hardware and software alarm system for enhanced operational safety

  • Flame Safety Controls: Automatic gas shutoff, shutdown sequence, and alarm activation during abnormal pressure, ignition failure, leakage, or unstable flow conditions

  • Independent Protection Modules: Emergency flame shutdown switch and high-current protection for furnace safety

Optional Functional Configurations

Flame Automatic Sampler (Optional)

  • Independent sampling system designed for flame analysis without disturbing furnace setup

  • Quick-release sample tray system for fast handling of standard and sample containers

  • Capacity for 70-position trays with ≥20 mL per cup using universal consumables

  • Automatic positioning, alignment correction, and high-flow multi-stage cleaning system

Oxygen-Enriched High-Temperature Flame (Optional)

Enables high-temperature element analysis such as aluminum, barium, molybdenum, and vanadium while avoiding hazardous oxidizing gases

Wide-Slit Combustion Head (Optional)

Supports complex sample stability with adjustable nebulizer for improved analytical consistency

Hydride Generation System (Optional)

Extends analytical capability for additional elements using hydride vapor techniques

Audit Trail Software (Optional)

Includes electronic signatures, user access control, and full process traceability for compliance with audit requirements

AAS - Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type) Dimensions and Weight

  • Main Unit: 1020mm×530mm×500mm(L×W×H), 85kg
  • Flame automatic sampler: 440mm×290mm×440mm(L×W×H), 14kg.
AAS - Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type) | Qualitest