Dry Contactless Ultrasonicator – QualiUltra™ DCL Series
The QualiUltra™ DCL Series Dry Contactless Ultrasonicator is a non-contact, sealed-tube processing system designed for handling trace and low-volume samples. Its probe-free architecture eliminates direct interaction between the sonication source and the sample, helping lower contamination risks while streamlining workflow setup compared to conventional probe-based systems.
This system uses a bottom-mounted ultrasonic module that delivers energy through sealed sample tubes, enabling efficient processing without opening or transferring contents. Integrated semiconductor-based cooling maintains a controlled low-temperature environment throughout operation, helping preserve the stability of temperature-sensitive biomolecules such as proteins and nucleic acids.
The QualiUltra™ DCL Series is optimized for rapid pretreatment in high-throughput molecular workflows, including nucleic acid preparation steps used in detection and analysis pipelines. Once processing is complete, samples can proceed directly into amplification, hybridization, or other downstream procedures with minimal handling, supporting smoother laboratory workflows.
Designed for compact bench-top use, this Ultrasonicator supports small-volume applications such as membrane disruption and cell lysis in sealed 2.0 mL tubes. It operates within a working volume range of 500–1000 µL, making it suitable for a wide variety of trace-sample protocols that require speed and consistency.
Temperature control is managed through an integrated semiconductor refrigeration system, maintaining a stable operating range of approximately 8–12°C during processing. This helps reduce heat-related degradation of sensitive biological targets. The system also supports stored parameter settings, allowing users to repeat optimized conditions for consistent experimental outcomes across multiple runs.
Dry Contactless Ultrasonicator – QualiUltra™ DCL Series Applications
Trace-sample pretreatment for rapid detection workflows
Supports fast processing of low-volume and trace samples where quick turnaround is essential. Designed for efficient preparation in time-sensitive detection and analytical pipelines.
Sealed-tube cell and bacteria disruption
Enables effective cell lysis and bacterial disruption inside sealed tubes without direct probe contact. This approach supports extraction of proteins, nucleic acids, and intracellular components while minimizing sample handling steps.
Nucleic acid amplification preparation
Processed samples are suitable for downstream amplification workflows, helping streamline the transition from sample preparation to analysis by reducing intermediate transfer steps.
Probe hybridization and detection preparation
Supports consistent sample conditioning for probe-based hybridization and molecular detection workflows. This helps maintain reliability in downstream diagnostic and analytical procedures.
Small-volume biomolecule extraction workflows
Well-suited for extracting target biomolecules such as proteins and nucleic acids from disrupted samples in low-volume formats. Integrated temperature control supports stability during processing, especially for heat-sensitive targets.
Standards Compliance – QualiUltra™ DCL Series
The QualiUltra™ DCL Series Dry Contactless Ultrasonicator is developed with alignment to internationally recognized laboratory and medical device standards, supporting safe operation, performance reliability, and structured quality management in regulated environments.
IEC 61010-1 – Laboratory Equipment Safety Requirements
Ensures general safety principles for electrical equipment used in laboratory, measurement, and control applications, focusing on operator protection and safe system design.
IEC 61326-1 – EMC Compliance (Immunity & Emissions)
Defines electromagnetic compatibility requirements for laboratory and measurement equipment, supporting stable performance without interference and controlled emission levels.
IEC 61010-2-101 – Safety Requirements for IVD Equipment
Specifies additional safety expectations for in vitro diagnostic (IVD) medical equipment, supporting safe handling in diagnostic and clinical workflows.
ISO 14971 – Medical Device Risk Management
Provides a structured framework for identifying, evaluating, and controlling risks associated with medical devices, including IVD systems, throughout the product lifecycle.
ISO 13485 – Medical Device Quality Management System
Defines quality management system requirements for medical device manufacturing, ensuring consistent design, production, and regulatory compliance processes.
Dry Contactless Ultrasonicator – QualiUltra™ DCL Series Key Features
Sealed-tube, dry non-contact processing
Enables sonication inside sealed tubes without direct probe interaction, supporting cleaner handling and reduced cross-sample interference.
Semiconductor-based temperature control system
Integrated cooling maintains stable low-temperature conditions during processing, helping preserve the integrity of temperature-sensitive biomolecules.
Rapid pretreatment for time-critical workflows
Designed for fast sample processing, with effective preparation achievable in approximately two minutes for compatible sample types, supporting high-throughput environments.
Reduced aerosol and mist formation risk
Non-contact energy transfer within sealed systems helps limit aerosol generation, supporting safer laboratory operation during disruption processes.
Compact and space-efficient design
A small footprint allows flexible placement in limited or high-density laboratory setups without requiring extensive bench space.
Compatible with multiple downstream workflows
Processed samples are suitable for further steps such as nucleic acid amplification, probe-based detection, purification, and related analytical procedures.
User-friendly operation with repeatable settings
Simple button-based controls with an LCD interface, along with stored parameter sets, support consistent operation and reproducible results across repeated runs.
Theory and Method – QualiUltra™ DCL Series Dry Contactless Ultrasonicator
The QualiUltra™ DCL Series operates using indirect ultrasonic energy transmission from a bottom-mounted ultrasound module into sealed sample tubes. This approach generates controlled mechanical forces through ultrasonic waves, enabling efficient cell disruption and membrane breakage without the need for probe immersion. By eliminating direct probe-to-sample contact, the system helps reduce contamination risk and simplifies routine laboratory handling.
A typical workflow begins by loading 500–1000 µL of sample into a compatible 2.0 mL sealed ultrasound tube. The tube is then placed into the instrument chamber, where operational parameters such as ultrasonic power level and total processing time are selected, with timing adjustable within a 1–900 second range depending on sample requirements.
During operation, an integrated semiconductor-based cooling system maintains a stable low-temperature environment, helping to protect temperature-sensitive biomolecules throughout the sonication process. After completion, the processed sample can be directly transferred to downstream applications such as nucleic acid amplification, hybridization assays, purification steps, or other analytical workflows without additional handling steps.
Dry Contactless Ultrasonicator – QualiUltra™ DCL Series Technical Specification
| Specification | QualiUltra™ DCL |
|---|---|
| Ultrasonic frequency | 20 kHz |
| Ultrasonic power | Max 30 W, adjustable in 10 levels |
| Sample throughput | 1 |
| Working volume | 500–1000 µL |
| Applicable consumables | 2.0 mL ultrasound sample tube |
| Timing range | 1–900 s |
| Temperature range | 8–12°C |
| Temperature control method | Semiconductor "parcel refrigeration" |
| Control method | Button control |
| Display | LCD |
| Stored programs / data | 99 sets |
| Voltage | 200–240 V, 50–60 Hz (110V is also available) |
| Overall power | 80 W |
| Operating environment | 15–30°C; RH ≤ 70% |
| Dimensions (L × W × H) | 155 × 208 × 193 mm |
| Weight | 2.6 kg |
Description
Dry Contactless Ultrasonicator – QualiUltra™ DCL Series
The QualiUltra™ DCL Series Dry Contactless Ultrasonicator is a non-contact, sealed-tube processing system designed for handling trace and low-volume samples. Its probe-free architecture eliminates direct interaction between the sonication source and the sample, helping lower contamination risks while streamlining workflow setup compared to conventional probe-based systems.
This system uses a bottom-mounted ultrasonic module that delivers energy through sealed sample tubes, enabling efficient processing without opening or transferring contents. Integrated semiconductor-based cooling maintains a controlled low-temperature environment throughout operation, helping preserve the stability of temperature-sensitive biomolecules such as proteins and nucleic acids.
The QualiUltra™ DCL Series is optimized for rapid pretreatment in high-throughput molecular workflows, including nucleic acid preparation steps used in detection and analysis pipelines. Once processing is complete, samples can proceed directly into amplification, hybridization, or other downstream procedures with minimal handling, supporting smoother laboratory workflows.
Designed for compact bench-top use, this Ultrasonicator supports small-volume applications such as membrane disruption and cell lysis in sealed 2.0 mL tubes. It operates within a working volume range of 500–1000 µL, making it suitable for a wide variety of trace-sample protocols that require speed and consistency.
Temperature control is managed through an integrated semiconductor refrigeration system, maintaining a stable operating range of approximately 8–12°C during processing. This helps reduce heat-related degradation of sensitive biological targets. The system also supports stored parameter settings, allowing users to repeat optimized conditions for consistent experimental outcomes across multiple runs.
Dry Contactless Ultrasonicator – QualiUltra™ DCL Series Applications
Trace-sample pretreatment for rapid detection workflows
Supports fast processing of low-volume and trace samples where quick turnaround is essential. Designed for efficient preparation in time-sensitive detection and analytical pipelines.
Sealed-tube cell and bacteria disruption
Enables effective cell lysis and bacterial disruption inside sealed tubes without direct probe contact. This approach supports extraction of proteins, nucleic acids, and intracellular components while minimizing sample handling steps.
Nucleic acid amplification preparation
Processed samples are suitable for downstream amplification workflows, helping streamline the transition from sample preparation to analysis by reducing intermediate transfer steps.
Probe hybridization and detection preparation
Supports consistent sample conditioning for probe-based hybridization and molecular detection workflows. This helps maintain reliability in downstream diagnostic and analytical procedures.
Small-volume biomolecule extraction workflows
Well-suited for extracting target biomolecules such as proteins and nucleic acids from disrupted samples in low-volume formats. Integrated temperature control supports stability during processing, especially for heat-sensitive targets.
Standards Compliance – QualiUltra™ DCL Series
The QualiUltra™ DCL Series Dry Contactless Ultrasonicator is developed with alignment to internationally recognized laboratory and medical device standards, supporting safe operation, performance reliability, and structured quality management in regulated environments.
IEC 61010-1 – Laboratory Equipment Safety Requirements
Ensures general safety principles for electrical equipment used in laboratory, measurement, and control applications, focusing on operator protection and safe system design.
IEC 61326-1 – EMC Compliance (Immunity & Emissions)
Defines electromagnetic compatibility requirements for laboratory and measurement equipment, supporting stable performance without interference and controlled emission levels.
IEC 61010-2-101 – Safety Requirements for IVD Equipment
Specifies additional safety expectations for in vitro diagnostic (IVD) medical equipment, supporting safe handling in diagnostic and clinical workflows.
ISO 14971 – Medical Device Risk Management
Provides a structured framework for identifying, evaluating, and controlling risks associated with medical devices, including IVD systems, throughout the product lifecycle.
ISO 13485 – Medical Device Quality Management System
Defines quality management system requirements for medical device manufacturing, ensuring consistent design, production, and regulatory compliance processes.
Dry Contactless Ultrasonicator – QualiUltra™ DCL Series Key Features
Sealed-tube, dry non-contact processing
Enables sonication inside sealed tubes without direct probe interaction, supporting cleaner handling and reduced cross-sample interference.
Semiconductor-based temperature control system
Integrated cooling maintains stable low-temperature conditions during processing, helping preserve the integrity of temperature-sensitive biomolecules.
Rapid pretreatment for time-critical workflows
Designed for fast sample processing, with effective preparation achievable in approximately two minutes for compatible sample types, supporting high-throughput environments.
Reduced aerosol and mist formation risk
Non-contact energy transfer within sealed systems helps limit aerosol generation, supporting safer laboratory operation during disruption processes.
Compact and space-efficient design
A small footprint allows flexible placement in limited or high-density laboratory setups without requiring extensive bench space.
Compatible with multiple downstream workflows
Processed samples are suitable for further steps such as nucleic acid amplification, probe-based detection, purification, and related analytical procedures.
User-friendly operation with repeatable settings
Simple button-based controls with an LCD interface, along with stored parameter sets, support consistent operation and reproducible results across repeated runs.
Theory and Method – QualiUltra™ DCL Series Dry Contactless Ultrasonicator
The QualiUltra™ DCL Series operates using indirect ultrasonic energy transmission from a bottom-mounted ultrasound module into sealed sample tubes. This approach generates controlled mechanical forces through ultrasonic waves, enabling efficient cell disruption and membrane breakage without the need for probe immersion. By eliminating direct probe-to-sample contact, the system helps reduce contamination risk and simplifies routine laboratory handling.
A typical workflow begins by loading 500–1000 µL of sample into a compatible 2.0 mL sealed ultrasound tube. The tube is then placed into the instrument chamber, where operational parameters such as ultrasonic power level and total processing time are selected, with timing adjustable within a 1–900 second range depending on sample requirements.
During operation, an integrated semiconductor-based cooling system maintains a stable low-temperature environment, helping to protect temperature-sensitive biomolecules throughout the sonication process. After completion, the processed sample can be directly transferred to downstream applications such as nucleic acid amplification, hybridization assays, purification steps, or other analytical workflows without additional handling steps.
Dry Contactless Ultrasonicator – QualiUltra™ DCL Series Technical Specification
| Specification | QualiUltra™ DCL |
|---|---|
| Ultrasonic frequency | 20 kHz |
| Ultrasonic power | Max 30 W, adjustable in 10 levels |
| Sample throughput | 1 |
| Working volume | 500–1000 µL |
| Applicable consumables | 2.0 mL ultrasound sample tube |
| Timing range | 1–900 s |
| Temperature range | 8–12°C |
| Temperature control method | Semiconductor "parcel refrigeration" |
| Control method | Button control |
| Display | LCD |
| Stored programs / data | 99 sets |
| Voltage | 200–240 V, 50–60 Hz (110V is also available) |
| Overall power | 80 W |
| Operating environment | 15–30°C; RH ≤ 70% |
| Dimensions (L × W × H) | 155 × 208 × 193 mm |
| Weight | 2.6 kg |