AAS Atomic Absorption Spectrophotometer - QT-AAS29 Series
AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series is designed for precise analytical performance in laboratory applications. It features PC control and an advanced optical system based on total reflection optics for stable and accurate measurements. The integrated gas control module along with pneumatic control ensures smooth and consistent operation, while burner adjustment supports optimized analytical conditions.
Background correction enhances measurement reliability in complex samples, and the modular design allows flexible system configuration based on testing requirements. The user-friendly software simplifies operation and data handling, while the safety protection system ensures secure use during analysis.
This system is suitable for element testing across petrochemistry, metallurgy, mining, geology, material analysis, food testing, and pharmacy applications.
AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series is an advanced analytical instrument designed to support precise laboratory analysis with a strong set of functional capabilities.
-
Total Reflection Optical System for improved optical efficiency and stable signal performance
-
Background Correction for enhanced accuracy in complex sample analysis
-
Automatic Pneumatic Control for smooth and reliable operation
-
Vertical 4/8-Lamp Turret supporting flexible multi-element analysis
-
Automatic Burner Adjustment for consistent and optimized flame conditions
-
Modular Design allowing flexible configuration based on application needs
-
User-Friendly Software for simplified operation and data management
-
Safety Protection System ensuring secure and stable instrument performance
Key Features of AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series:
Total Reflection Optical System: Reduces energy loss, delivering a high signal-to-noise ratio and supporting lower detection limits for improved analytical precision.
Background Correction: Standard deuterium lamp background correction is available across all models. Double beam configurations include advanced self-absorption background correction as standard, with optional support for systems featuring an 8-lamp turret.
Automatic Pneumatic Control: An integrated pneumatic control module improves operational stability and measurement accuracy while supporting safe instrument handling for both user and system.
Vertical 4/8-Lamp Turret: Designed for high-performance element lamps, the vertical turret offers 360-degree rotation, ensuring consistent performance and accurate results independent of gravitational effects.
Automatic Burner Adjustment: Enables optimized flame conditions through precise burner positioning based on real-time readings. Built-in flame detection further strengthens operational safety.
Modular Design: Both optical and electronic systems are built with a modular structure, allowing easier servicing, maintenance, and system upgrades.
User-Friendly Software: Operates through RGWIN AAS software on MS Windows, providing an intuitive interface with automated functions, professional tools, and integrated QA/QC features.
Safety Protection System: Includes flame monitoring, automatic acetylene shutoff during abnormal conditions, acetylene leak alerts, and pressure monitoring to prevent operation outside safe limits.
The AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series supports precise and dependable elemental analysis across a wide range of applications, including petrochemistry, metallurgy, mining, geology, material analysis, food testing, and pharmaceutical research.
AAS Atomic Absorption Spectrophotometer - QT-AAS29 Series
|
Model |
QT-AAS2914 |
QT-AAS2918 |
QT-AAS2928 |
|
|
Optical System |
Optical Type |
Single beam |
Single beam |
Double beam |
|
Monochromator |
Czerny-Turner type with focal lengths at 350mm |
|||
|
Wavelength Range |
190-900nm |
|||
|
Grating |
Holographic diffraction grating with 1800 lines/mm |
|||
|
Slits |
Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm |
|||
|
Wavelength Accuracy |
±0.3 nm |
±0.2 nm |
±0.15 nm |
|
|
Wavelength Repeatability |
±0.1nm |
±0.1nm |
±0.05nm |
|
|
Lamp Holder |
Automated 4-lamp turret |
Automated 8-lamp turret |
||
|
Detector |
Wide range UV sensitive photomultiplier tube |
|||
|
Photometric Performance |
Reading Mode |
Transmittance(T), Absorbance(A), Concentration(C) |
||
|
Photometric Range |
0-125%, -0.1-3.00A |
|||
|
Static Baseline Drift (Cu) |
≤0.004A/30 min |
≤0.003A/30 min |
≤0.002A/30 min |
|
|
Dynamic Baseline Drift (Cu) |
≤0.006A/15 min |
≤0.005A/15 min |
≤0.004A/15 min |
|
|
Background Correction |
Deuterium (D2) Background Correction |
D2 and Self-absorption |
||
|
Flame Analysis |
Characteristic Concentration |
Cu≤0.04ug/ml |
Cu≤0.035ug/ml |
Cu≤0.02ug/ml |
|
Detection Limit |
Cu≤0.008ug/ml |
Cu≤0.006ug/ml |
Cu≤0.004ug/ml |
|
|
Repeatability (Cu) |
RSD≤1% |
RSD≤0.6% |
RSD≤0.5% |
|
|
Acetylene Flow Control |
Auto 12-level |
Auto 12-level |
Auto 12-level |
|
|
Air Flow Control |
Auto 4-level |
Auto 4-level |
Auto 4-level |
|
|
Nebulizer |
High efficiency glass |
|||
|
Burner Adjustment |
Automatic up and down |
|||
|
Burner Head |
Titanium alloy 100mm burner for air/acetylene operation |
|||
|
Premix Chamber |
Corrosion resistant |
|||
|
Safety Protection |
Flame sensor, gas leak sensor, gas pressure sensor |
|||
|
Data Processing |
Software |
RGWIN AAS software pacakage |
||
|
Analytical Method |
Flame AA, Flame AE, Hydride Generation |
|||
|
Concentration Calculation Method |
Standard curve(6 linear/non-linear fitting), Standard Addition, Interpolation |
|||
|
Repeated Measurement Times |
1-30 times, calculate the average, show SD and RSD value of absorbance and concentration |
|||
|
QA/QC Function |
Correlation coefficient, SD & RSD of Abs and calculate SD & RSD of concentration |
|||
|
Report Printing |
Parameter printing, resulting printing |
|||
|
Communication Port |
Standard RS-232 |
|||
|
Others |
Computer |
External(excluded) |
||
|
Dimension & Weight |
850*650*550MM(W*D*H), 100Kg |
|||
|
Power Supply |
110/220V, 50/60Hz |
|||
|
Working Environment |
Temperature 10 ~ 35 °C, Humidity≦85% |
|||
Packing List
|
NO. |
Description |
Qty |
NO. |
Description |
Qty |
|
1 |
Main Unit |
1 |
8 |
6mm air tube(transparent) |
10m |
|
2 |
Power Cable |
1 |
9 |
USB(manual and software) |
1 |
|
3 |
Data Cable |
1 |
10 |
Drain Tube |
2m |
|
4 |
Screw Driver |
1 |
11 |
Acetylene pressure reducing valve connector |
1 |
|
5 |
Cu HCL |
1 |
12 |
5A fuse |
3 |
|
6 |
Air Compressor |
1 |
13 |
Ignition filament |
5 |
|
7 |
6mm acetylene tube(orange) |
10m |
|
||
Description
AAS Atomic Absorption Spectrophotometer - QT-AAS29 Series
AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series is designed for precise analytical performance in laboratory applications. It features PC control and an advanced optical system based on total reflection optics for stable and accurate measurements. The integrated gas control module along with pneumatic control ensures smooth and consistent operation, while burner adjustment supports optimized analytical conditions.
Background correction enhances measurement reliability in complex samples, and the modular design allows flexible system configuration based on testing requirements. The user-friendly software simplifies operation and data handling, while the safety protection system ensures secure use during analysis.
This system is suitable for element testing across petrochemistry, metallurgy, mining, geology, material analysis, food testing, and pharmacy applications.
AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series is an advanced analytical instrument designed to support precise laboratory analysis with a strong set of functional capabilities.
-
Total Reflection Optical System for improved optical efficiency and stable signal performance
-
Background Correction for enhanced accuracy in complex sample analysis
-
Automatic Pneumatic Control for smooth and reliable operation
-
Vertical 4/8-Lamp Turret supporting flexible multi-element analysis
-
Automatic Burner Adjustment for consistent and optimized flame conditions
-
Modular Design allowing flexible configuration based on application needs
-
User-Friendly Software for simplified operation and data management
-
Safety Protection System ensuring secure and stable instrument performance
Key Features of AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series:
Total Reflection Optical System: Reduces energy loss, delivering a high signal-to-noise ratio and supporting lower detection limits for improved analytical precision.
Background Correction: Standard deuterium lamp background correction is available across all models. Double beam configurations include advanced self-absorption background correction as standard, with optional support for systems featuring an 8-lamp turret.
Automatic Pneumatic Control: An integrated pneumatic control module improves operational stability and measurement accuracy while supporting safe instrument handling for both user and system.
Vertical 4/8-Lamp Turret: Designed for high-performance element lamps, the vertical turret offers 360-degree rotation, ensuring consistent performance and accurate results independent of gravitational effects.
Automatic Burner Adjustment: Enables optimized flame conditions through precise burner positioning based on real-time readings. Built-in flame detection further strengthens operational safety.
Modular Design: Both optical and electronic systems are built with a modular structure, allowing easier servicing, maintenance, and system upgrades.
User-Friendly Software: Operates through RGWIN AAS software on MS Windows, providing an intuitive interface with automated functions, professional tools, and integrated QA/QC features.
Safety Protection System: Includes flame monitoring, automatic acetylene shutoff during abnormal conditions, acetylene leak alerts, and pressure monitoring to prevent operation outside safe limits.
The AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series supports precise and dependable elemental analysis across a wide range of applications, including petrochemistry, metallurgy, mining, geology, material analysis, food testing, and pharmaceutical research.
AAS Atomic Absorption Spectrophotometer - QT-AAS29 Series
|
Model |
QT-AAS2914 |
QT-AAS2918 |
QT-AAS2928 |
|
|
Optical System |
Optical Type |
Single beam |
Single beam |
Double beam |
|
Monochromator |
Czerny-Turner type with focal lengths at 350mm |
|||
|
Wavelength Range |
190-900nm |
|||
|
Grating |
Holographic diffraction grating with 1800 lines/mm |
|||
|
Slits |
Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm |
|||
|
Wavelength Accuracy |
±0.3 nm |
±0.2 nm |
±0.15 nm |
|
|
Wavelength Repeatability |
±0.1nm |
±0.1nm |
±0.05nm |
|
|
Lamp Holder |
Automated 4-lamp turret |
Automated 8-lamp turret |
||
|
Detector |
Wide range UV sensitive photomultiplier tube |
|||
|
Photometric Performance |
Reading Mode |
Transmittance(T), Absorbance(A), Concentration(C) |
||
|
Photometric Range |
0-125%, -0.1-3.00A |
|||
|
Static Baseline Drift (Cu) |
≤0.004A/30 min |
≤0.003A/30 min |
≤0.002A/30 min |
|
|
Dynamic Baseline Drift (Cu) |
≤0.006A/15 min |
≤0.005A/15 min |
≤0.004A/15 min |
|
|
Background Correction |
Deuterium (D2) Background Correction |
D2 and Self-absorption |
||
|
Flame Analysis |
Characteristic Concentration |
Cu≤0.04ug/ml |
Cu≤0.035ug/ml |
Cu≤0.02ug/ml |
|
Detection Limit |
Cu≤0.008ug/ml |
Cu≤0.006ug/ml |
Cu≤0.004ug/ml |
|
|
Repeatability (Cu) |
RSD≤1% |
RSD≤0.6% |
RSD≤0.5% |
|
|
Acetylene Flow Control |
Auto 12-level |
Auto 12-level |
Auto 12-level |
|
|
Air Flow Control |
Auto 4-level |
Auto 4-level |
Auto 4-level |
|
|
Nebulizer |
High efficiency glass |
|||
|
Burner Adjustment |
Automatic up and down |
|||
|
Burner Head |
Titanium alloy 100mm burner for air/acetylene operation |
|||
|
Premix Chamber |
Corrosion resistant |
|||
|
Safety Protection |
Flame sensor, gas leak sensor, gas pressure sensor |
|||
|
Data Processing |
Software |
RGWIN AAS software pacakage |
||
|
Analytical Method |
Flame AA, Flame AE, Hydride Generation |
|||
|
Concentration Calculation Method |
Standard curve(6 linear/non-linear fitting), Standard Addition, Interpolation |
|||
|
Repeated Measurement Times |
1-30 times, calculate the average, show SD and RSD value of absorbance and concentration |
|||
|
QA/QC Function |
Correlation coefficient, SD & RSD of Abs and calculate SD & RSD of concentration |
|||
|
Report Printing |
Parameter printing, resulting printing |
|||
|
Communication Port |
Standard RS-232 |
|||
|
Others |
Computer |
External(excluded) |
||
|
Dimension & Weight |
850*650*550MM(W*D*H), 100Kg |
|||
|
Power Supply |
110/220V, 50/60Hz |
|||
|
Working Environment |
Temperature 10 ~ 35 °C, Humidity≦85% |
|||
Packing List
|
NO. |
Description |
Qty |
NO. |
Description |
Qty |
|
1 |
Main Unit |
1 |
8 |
6mm air tube(transparent) |
10m |
|
2 |
Power Cable |
1 |
9 |
USB(manual and software) |
1 |
|
3 |
Data Cable |
1 |
10 |
Drain Tube |
2m |
|
4 |
Screw Driver |
1 |
11 |
Acetylene pressure reducing valve connector |
1 |
|
5 |
Cu HCL |
1 |
12 |
5A fuse |
3 |
|
6 |
Air Compressor |
1 |
13 |
Ignition filament |
5 |
|
7 |
6mm acetylene tube(orange) |
10m |
|
||