AAS Atomic Absorption Spectrophotometer - QT-AAS29 Series
HomeStore

AAS Atomic Absorption Spectrophotometer - QT-AAS29 Series

AAS Atomic Absorption Spectrophotometer - QT-AAS29 Series

$35.00

Original: $100.00

-65%
AAS Atomic Absorption Spectrophotometer - QT-AAS29 Series

$100.00

$35.00

The Story

AAS Atomic Absorption Spectrophotometer - QT-AAS29 Series

AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series is designed for precise analytical performance in laboratory applications. It features PC control and an advanced optical system based on total reflection optics for stable and accurate measurements. The integrated gas control module along with pneumatic control ensures smooth and consistent operation, while burner adjustment supports optimized analytical conditions.

Background correction enhances measurement reliability in complex samples, and the modular design allows flexible system configuration based on testing requirements. The user-friendly software simplifies operation and data handling, while the safety protection system ensures secure use during analysis.

This system is suitable for element testing across petrochemistry, metallurgy, mining, geology, material analysis, food testing, and pharmacy applications.

AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series is an advanced analytical instrument designed to support precise laboratory analysis with a strong set of functional capabilities.

  • Total Reflection Optical System for improved optical efficiency and stable signal performance

  • Background Correction for enhanced accuracy in complex sample analysis

  • Automatic Pneumatic Control for smooth and reliable operation

  • Vertical 4/8-Lamp Turret supporting flexible multi-element analysis

  • Automatic Burner Adjustment for consistent and optimized flame conditions

  • Modular Design allowing flexible configuration based on application needs

  • User-Friendly Software for simplified operation and data management

  • Safety Protection System ensuring secure and stable instrument performance

Key Features of AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series:

Total Reflection Optical System: Reduces energy loss, delivering a high signal-to-noise ratio and supporting lower detection limits for improved analytical precision.

Background Correction: Standard deuterium lamp background correction is available across all models. Double beam configurations include advanced self-absorption background correction as standard, with optional support for systems featuring an 8-lamp turret.

Automatic Pneumatic Control: An integrated pneumatic control module improves operational stability and measurement accuracy while supporting safe instrument handling for both user and system.

Vertical 4/8-Lamp Turret: Designed for high-performance element lamps, the vertical turret offers 360-degree rotation, ensuring consistent performance and accurate results independent of gravitational effects.

Automatic Burner Adjustment: Enables optimized flame conditions through precise burner positioning based on real-time readings. Built-in flame detection further strengthens operational safety.

Modular Design: Both optical and electronic systems are built with a modular structure, allowing easier servicing, maintenance, and system upgrades.

User-Friendly Software: Operates through RGWIN AAS software on MS Windows, providing an intuitive interface with automated functions, professional tools, and integrated QA/QC features.

Safety Protection System: Includes flame monitoring, automatic acetylene shutoff during abnormal conditions, acetylene leak alerts, and pressure monitoring to prevent operation outside safe limits.

The AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series supports precise and dependable elemental analysis across a wide range of applications, including petrochemistry, metallurgy, mining, geology, material analysis, food testing, and pharmaceutical research.

AAS Atomic Absorption Spectrophotometer - QT-AAS29 Series

Model

QT-AAS2914

QT-AAS2918

QT-AAS2928

Optical System

Optical Type

Single beam

Single beam

Double beam

Monochromator

Czerny-Turner type with focal lengths at 350mm

Wavelength Range

190-900nm

Grating

Holographic diffraction grating with 1800 lines/mm

Slits

Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm

Wavelength Accuracy

±0.3 nm

±0.2 nm

±0.15 nm

Wavelength Repeatability

±0.1nm

±0.1nm

±0.05nm

Lamp Holder

Automated 4-lamp turret

Automated 8-lamp turret

Detector

Wide range UV sensitive photomultiplier tube

Photometric

Performance

Reading Mode

Transmittance(T), Absorbance(A), Concentration(C)

Photometric Range

0-125%, -0.1-3.00A

Static Baseline Drift (Cu)

≤0.004A/30 min

≤0.003A/30 min

≤0.002A/30 min

Dynamic Baseline Drift (Cu)

≤0.006A/15 min

≤0.005A/15 min

≤0.004A/15 min

Background Correction

Deuterium (D2) Background Correction

D2 and Self-absorption

Flame Analysis

Characteristic Concentration

Cu≤0.04ug/ml

Cu≤0.035ug/ml

Cu≤0.02ug/ml

Detection Limit

Cu≤0.008ug/ml

Cu≤0.006ug/ml

Cu≤0.004ug/ml

Repeatability (Cu)

RSD≤1%

RSD≤0.6%

RSD≤0.5%

Acetylene Flow Control

Auto 12-level

Auto 12-level

Auto 12-level

Air Flow Control

Auto 4-level

Auto 4-level

Auto 4-level

Nebulizer

High efficiency glass

Burner Adjustment

Automatic up and down

Burner Head

Titanium alloy 100mm burner for air/acetylene operation

Premix Chamber

Corrosion resistant

Safety Protection

Flame sensor, gas leak sensor, gas pressure sensor

Data Processing

Software

RGWIN AAS software pacakage

Analytical Method

Flame AA, Flame AE, Hydride Generation

Concentration Calculation

Method

Standard curve(6 linear/non-linear fitting), Standard Addition, Interpolation

Repeated Measurement Times

1-30 times, calculate the average, show SD and RSD value of absorbance and concentration

QA/QC Function

Correlation coefficient, SD & RSD of Abs and calculate SD & RSD of concentration

Report Printing

Parameter printing, resulting printing

Communication Port

Standard RS-232

Others

Computer

External(excluded)

Dimension & Weight

850*650*550MM(W*D*H), 100Kg

Power Supply

110/220V, 50/60Hz

Working Environment

Temperature 10 ~ 35 °C, Humidity≦85%

 

Packing List

NO.

Description

Qty

NO.

Description

Qty

1

Main Unit

1

8

6mm air tube(transparent)

10m

2

Power Cable

1

9

USB(manual and software)

1

3

Data Cable

1

10

Drain Tube

2m

4

Screw Driver

1

11

Acetylene pressure reducing valve connector

1

5

Cu HCL

1

12

5A fuse

3

6

Air Compressor

1

13

Ignition filament

5

7

6mm acetylene tube(orange)

10m

 

 

Description

AAS Atomic Absorption Spectrophotometer - QT-AAS29 Series

AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series is designed for precise analytical performance in laboratory applications. It features PC control and an advanced optical system based on total reflection optics for stable and accurate measurements. The integrated gas control module along with pneumatic control ensures smooth and consistent operation, while burner adjustment supports optimized analytical conditions.

Background correction enhances measurement reliability in complex samples, and the modular design allows flexible system configuration based on testing requirements. The user-friendly software simplifies operation and data handling, while the safety protection system ensures secure use during analysis.

This system is suitable for element testing across petrochemistry, metallurgy, mining, geology, material analysis, food testing, and pharmacy applications.

AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series is an advanced analytical instrument designed to support precise laboratory analysis with a strong set of functional capabilities.

  • Total Reflection Optical System for improved optical efficiency and stable signal performance

  • Background Correction for enhanced accuracy in complex sample analysis

  • Automatic Pneumatic Control for smooth and reliable operation

  • Vertical 4/8-Lamp Turret supporting flexible multi-element analysis

  • Automatic Burner Adjustment for consistent and optimized flame conditions

  • Modular Design allowing flexible configuration based on application needs

  • User-Friendly Software for simplified operation and data management

  • Safety Protection System ensuring secure and stable instrument performance

Key Features of AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series:

Total Reflection Optical System: Reduces energy loss, delivering a high signal-to-noise ratio and supporting lower detection limits for improved analytical precision.

Background Correction: Standard deuterium lamp background correction is available across all models. Double beam configurations include advanced self-absorption background correction as standard, with optional support for systems featuring an 8-lamp turret.

Automatic Pneumatic Control: An integrated pneumatic control module improves operational stability and measurement accuracy while supporting safe instrument handling for both user and system.

Vertical 4/8-Lamp Turret: Designed for high-performance element lamps, the vertical turret offers 360-degree rotation, ensuring consistent performance and accurate results independent of gravitational effects.

Automatic Burner Adjustment: Enables optimized flame conditions through precise burner positioning based on real-time readings. Built-in flame detection further strengthens operational safety.

Modular Design: Both optical and electronic systems are built with a modular structure, allowing easier servicing, maintenance, and system upgrades.

User-Friendly Software: Operates through RGWIN AAS software on MS Windows, providing an intuitive interface with automated functions, professional tools, and integrated QA/QC features.

Safety Protection System: Includes flame monitoring, automatic acetylene shutoff during abnormal conditions, acetylene leak alerts, and pressure monitoring to prevent operation outside safe limits.

The AAS Atomic Absorption Spectrophotometer – QT-AAS29 Series supports precise and dependable elemental analysis across a wide range of applications, including petrochemistry, metallurgy, mining, geology, material analysis, food testing, and pharmaceutical research.

AAS Atomic Absorption Spectrophotometer - QT-AAS29 Series

Model

QT-AAS2914

QT-AAS2918

QT-AAS2928

Optical System

Optical Type

Single beam

Single beam

Double beam

Monochromator

Czerny-Turner type with focal lengths at 350mm

Wavelength Range

190-900nm

Grating

Holographic diffraction grating with 1800 lines/mm

Slits

Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm

Wavelength Accuracy

±0.3 nm

±0.2 nm

±0.15 nm

Wavelength Repeatability

±0.1nm

±0.1nm

±0.05nm

Lamp Holder

Automated 4-lamp turret

Automated 8-lamp turret

Detector

Wide range UV sensitive photomultiplier tube

Photometric

Performance

Reading Mode

Transmittance(T), Absorbance(A), Concentration(C)

Photometric Range

0-125%, -0.1-3.00A

Static Baseline Drift (Cu)

≤0.004A/30 min

≤0.003A/30 min

≤0.002A/30 min

Dynamic Baseline Drift (Cu)

≤0.006A/15 min

≤0.005A/15 min

≤0.004A/15 min

Background Correction

Deuterium (D2) Background Correction

D2 and Self-absorption

Flame Analysis

Characteristic Concentration

Cu≤0.04ug/ml

Cu≤0.035ug/ml

Cu≤0.02ug/ml

Detection Limit

Cu≤0.008ug/ml

Cu≤0.006ug/ml

Cu≤0.004ug/ml

Repeatability (Cu)

RSD≤1%

RSD≤0.6%

RSD≤0.5%

Acetylene Flow Control

Auto 12-level

Auto 12-level

Auto 12-level

Air Flow Control

Auto 4-level

Auto 4-level

Auto 4-level

Nebulizer

High efficiency glass

Burner Adjustment

Automatic up and down

Burner Head

Titanium alloy 100mm burner for air/acetylene operation

Premix Chamber

Corrosion resistant

Safety Protection

Flame sensor, gas leak sensor, gas pressure sensor

Data Processing

Software

RGWIN AAS software pacakage

Analytical Method

Flame AA, Flame AE, Hydride Generation

Concentration Calculation

Method

Standard curve(6 linear/non-linear fitting), Standard Addition, Interpolation

Repeated Measurement Times

1-30 times, calculate the average, show SD and RSD value of absorbance and concentration

QA/QC Function

Correlation coefficient, SD & RSD of Abs and calculate SD & RSD of concentration

Report Printing

Parameter printing, resulting printing

Communication Port

Standard RS-232

Others

Computer

External(excluded)

Dimension & Weight

850*650*550MM(W*D*H), 100Kg

Power Supply

110/220V, 50/60Hz

Working Environment

Temperature 10 ~ 35 °C, Humidity≦85%

 

Packing List

NO.

Description

Qty

NO.

Description

Qty

1

Main Unit

1

8

6mm air tube(transparent)

10m

2

Power Cable

1

9

USB(manual and software)

1

3

Data Cable

1

10

Drain Tube

2m

4

Screw Driver

1

11

Acetylene pressure reducing valve connector

1

5

Cu HCL

1

12

5A fuse

3

6

Air Compressor

1

13

Ignition filament

5

7

6mm acetylene tube(orange)

10m

 

 
AAS Atomic Absorption Spectrophotometer - QT-AAS29 Series | Qualitest