
Original: $100.00
-65%$100.00
$35.00The Story
AAS Atomic Absorption Spectrophotometer - QT-AAS60 Series
AAS Atomic Absorption Spectrophotometer - QT-AAS60 Series delivers advanced analytical performance for precise laboratory applications. Designed with full PC control, it features a sleek, modern, and space-saving structure that fits seamlessly into diverse lab environments.
This system offers high flexibility with configurable setups and a broad selection of accessories to support varied testing requirements. Its advanced optical system provides consistent stability and dependable measurement accuracy, ensuring high-quality analytical results.
An intelligent gas control module enhances operational safety and system reliability, making the QT-AAS60 Series a strong choice for laboratories seeking efficient, accurate, and secure elemental analysis solutions.
Total Reflection Optical System: Reduces signal loss to enhance sensitivity and measurement accuracy.
- Background Correction: Improves analytical reliability by minimizing interference effects.
- Automatic Pneumatic Control Module: Ensures stable operation and improved system efficiency.
- Automatic Vertical 4/8-Lamp Turret: Supports multiple light sources for flexible and efficient analysis.
- Automatic Burner Adjustment: Optimizes flame position for consistent performance.
- Modular Design: Simplifies maintenance and allows flexible system configuration.
- User-Friendly Software: Provides intuitive operation and efficient workflow management.
- Transversely Heated Graphite Tube: Enhances temperature control for improved detection capability.
- Comprehensive Safety Protection System: Delivers enhanced operational safety and system protection.
This advanced configuration makes the QT-AAS60 Series a reliable solution for laboratories focused on precision, efficiency, and analytical consistency.
Key Features of AAS Atomic Absorption Spectrophotometer - QT-AAS60 Series
Total Reflection Optical System:
This advanced optical design reduces energy loss, delivering a strong signal-to-noise ratio and improved detection sensitivity for more precise analytical results.
Background Correction:
All models include deuterium lamp background correction as standard. Double beam configurations feature high-performance self-absorption correction, while models with an 8-lamp turret offer this as an optional enhancement, improving accuracy in complex sample analysis.
Automatic Pneumatic Control Module:
Provides stable operation with enhanced safety and measurement precision, offering reliable protection for both users and instrument components.
Automatic Vertical 4/8-Lamp Turret:
Designed for high-performance element lamps with smooth 360-degree rotation, this system ensures accurate, stable readings without gravitational interference.
Automatic Burner Adjustment:
Allows precise flame positioning by automatically adjusting burner height, optimizing sensitivity based on analytical requirements. Integrated flame monitoring adds an extra layer of operational safety.
Modular Design:
Both optical and electronic systems are built with a modular structure, making maintenance, servicing, and upgrades more efficient and convenient.
User-Friendly Software:
Operates on RGWIN AAS software under MS Windows, offering an intuitive interface with automated functions and built-in QA/QC tools to streamline workflows and improve productivity.
Transversely Heated Graphite Tube:
Ensures uniform gas temperature distribution and rapid attainment of atomic conditions, improving atomization efficiency, analytical accuracy, and extending system lifespan while reducing maintenance demand.
Comprehensive Safety Protection System:
Includes flame monitoring, automatic acetylene shutoff during abnormal conditions, gas leak alerts, and pressure monitoring for air and acetylene. The system also restricts graphite furnace operation under unsafe argon pressure levels and performs self-checks for correct tube installation, ensuring maximum operational safety and reliability.
Technical Specifications
|
Model |
AA6018 |
AA6028 |
|
|
Optical System |
Optical Type |
Single beam |
Double beam |
|
Monochromator |
Czerny-Turner type with focal lengths at 350mm |
||
|
Wavelength Range |
190-900nm |
||
|
Grating |
Holographic diffraction grating with 1800 lines/mm |
||
|
Slits |
Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm |
||
|
Wavelength Accuracy |
±0.2 nm |
±0.15 nm |
|
|
Wavelength Repeatability |
±0.1nm |
±0.05nm |
|
|
Lamp Holder |
Automated 8-lamp turret |
||
|
Detector |
Wide range UV sensitive photomultiplier tube |
||
|
Photometric Performance |
Reading Mode |
Transmittance(T), Absorbance(A), Concentration(C) |
|
|
Photometric Range |
0-125%, -0.1-3.00A |
||
|
Static Baseline Drift (Cu) |
≤0.003A/30 min |
≤0.002A/30 min |
|
|
Dynamic Baseline Drift (Cu) |
≤0.005A/15 min |
≤0.004A/15 min |
|
|
Background Correction |
Deuterium (D2) Background Correction and Self-absorption Background Correction |
||
|
Flame Analysis |
Characteristic Concentration |
Cu≤0.035ug/ml |
Cu≤0.02ug/ml |
|
Detection Limit |
Cu≤0.006ug/ml |
Cu≤0.004ug/ml |
|
|
Repeatability (Cu) |
RSD≤0.6% |
RSD≤0.5% |
|
|
Acetylene Flow Control |
Auto 12-level |
Auto 12-level |
|
|
Air Flow Control |
Auto 4-level |
Auto 4-level |
|
|
Nebulizer |
High efficiency glass |
||
|
Burner Adjustment |
Automatic up and down |
||
|
Burner Head |
Titanium alloy 100mm burner for air/acetylene operation |
||
|
Premix Chamber |
Corrosion resistant |
||
|
Safety Protection |
Flame sensor, gas leak sensor, gas pressure sensor |
||
|
Graphite Furnace Analysis |
Characteristic Concentration |
Cd≤0.6pg , Cu≤20pg |
Cd≤0.5pg , Cu≤20pg |
|
Detection Limit |
Cd≤1.0pg , Cu≤25pg |
Cd≤0.8pg , Cu≤25pg |
|
|
Repeatability (Cu) |
RSD≤3% |
RSD≤2.5% |
|
|
Temperature Range |
Ambient -3000℃ |
Ambient -3000℃ |
|
|
Ramp and holding time |
1-255s |
1-255s |
|
|
Heating Rate |
Maximum linear heating rate 2000℃/s |
||
|
Atomization Heating Method |
Light-controlled heating, Time-controlled heating, General heating |
||
|
Gas Flow Rate Inside Tube |
1 L/min |
1 L/min |
|
|
Gas Flow Rate Outside Tube |
4-speed adjustable (0, 50, 200, 250ml/min) |
||
|
Safety Protection |
Water flow sensor, Argon pressure sensor, Furnace body temperature sensor, Graphite tube installation self-inspection. |
||
|
Data Processing |
Software |
RGWIN AAS software package |
|
|
Analytical Method |
Flame AA, Flame AE, Hydride Generation |
||
|
Concentration Calculation Method |
Standard curve(6 linear/non-linear fitting), Standard Addition, Interpolation |
||
|
Repeated Measurement Times |
1-30 times, calculate the average, show SD and RSD value of absorbance and concentration |
||
|
QA/QC Function |
Correlation coefficient, SD & RSD of Abs and calculate SD & RSD of concentration |
||
|
Report Printing |
Parameter printing, resulting printing |
||
|
Communication Port |
Standard RS-232 |
||
|
Others |
Computer |
External(excluded) |
|
|
Dimension & Weight |
850*650*550MM(W*D*H), 100Kg |
||
|
Power Supply |
110/220V, 50/60Hz |
||
|
Working Environment |
Temperature 10 ~ 35 °C, Humidity≦85% |
||
Packing List
|
NO. |
Description |
Qty |
NO. |
Description |
Qty |
|
1 |
Main Unit |
1 |
12 |
Acetylene pressure reducing valve connector |
1 |
|
2 |
Power Cable |
1 |
13 |
5A fuse |
3 |
|
3 |
Data Cable |
1 |
14 |
Argon pressure reducing valve connector |
1 |
|
4 |
Screw Driver |
1 |
15 |
Graphite tube |
5 |
|
5 |
Cu HCL |
1 |
16 |
High power socket |
1 |
|
6 |
Cd HCL |
1 |
17 |
6*4mm argon tube(transparent) |
10m |
|
7 |
Air Compressor |
1 |
18 |
5-50ul pipette |
1 |
|
8 |
6mm acetylene tube(orange) |
10m |
19 |
200ul pipette tip(1000pc/bag) |
1 |
|
9 |
6mm air tube(transparent) |
10m |
20 |
6*10mm cooling water tube |
6m |
|
10 |
USB(manual and software) |
1 |
21 |
Graphite furnace camera connection cable |
1 |
|
11 |
Drain Tube |
2m |
22 |
Ignition filament |
5 |
Description
AAS Atomic Absorption Spectrophotometer - QT-AAS60 Series
AAS Atomic Absorption Spectrophotometer - QT-AAS60 Series delivers advanced analytical performance for precise laboratory applications. Designed with full PC control, it features a sleek, modern, and space-saving structure that fits seamlessly into diverse lab environments.
This system offers high flexibility with configurable setups and a broad selection of accessories to support varied testing requirements. Its advanced optical system provides consistent stability and dependable measurement accuracy, ensuring high-quality analytical results.
An intelligent gas control module enhances operational safety and system reliability, making the QT-AAS60 Series a strong choice for laboratories seeking efficient, accurate, and secure elemental analysis solutions.
Total Reflection Optical System: Reduces signal loss to enhance sensitivity and measurement accuracy.
- Background Correction: Improves analytical reliability by minimizing interference effects.
- Automatic Pneumatic Control Module: Ensures stable operation and improved system efficiency.
- Automatic Vertical 4/8-Lamp Turret: Supports multiple light sources for flexible and efficient analysis.
- Automatic Burner Adjustment: Optimizes flame position for consistent performance.
- Modular Design: Simplifies maintenance and allows flexible system configuration.
- User-Friendly Software: Provides intuitive operation and efficient workflow management.
- Transversely Heated Graphite Tube: Enhances temperature control for improved detection capability.
- Comprehensive Safety Protection System: Delivers enhanced operational safety and system protection.
This advanced configuration makes the QT-AAS60 Series a reliable solution for laboratories focused on precision, efficiency, and analytical consistency.
Key Features of AAS Atomic Absorption Spectrophotometer - QT-AAS60 Series
Total Reflection Optical System:
This advanced optical design reduces energy loss, delivering a strong signal-to-noise ratio and improved detection sensitivity for more precise analytical results.
Background Correction:
All models include deuterium lamp background correction as standard. Double beam configurations feature high-performance self-absorption correction, while models with an 8-lamp turret offer this as an optional enhancement, improving accuracy in complex sample analysis.
Automatic Pneumatic Control Module:
Provides stable operation with enhanced safety and measurement precision, offering reliable protection for both users and instrument components.
Automatic Vertical 4/8-Lamp Turret:
Designed for high-performance element lamps with smooth 360-degree rotation, this system ensures accurate, stable readings without gravitational interference.
Automatic Burner Adjustment:
Allows precise flame positioning by automatically adjusting burner height, optimizing sensitivity based on analytical requirements. Integrated flame monitoring adds an extra layer of operational safety.
Modular Design:
Both optical and electronic systems are built with a modular structure, making maintenance, servicing, and upgrades more efficient and convenient.
User-Friendly Software:
Operates on RGWIN AAS software under MS Windows, offering an intuitive interface with automated functions and built-in QA/QC tools to streamline workflows and improve productivity.
Transversely Heated Graphite Tube:
Ensures uniform gas temperature distribution and rapid attainment of atomic conditions, improving atomization efficiency, analytical accuracy, and extending system lifespan while reducing maintenance demand.
Comprehensive Safety Protection System:
Includes flame monitoring, automatic acetylene shutoff during abnormal conditions, gas leak alerts, and pressure monitoring for air and acetylene. The system also restricts graphite furnace operation under unsafe argon pressure levels and performs self-checks for correct tube installation, ensuring maximum operational safety and reliability.
Technical Specifications
|
Model |
AA6018 |
AA6028 |
|
|
Optical System |
Optical Type |
Single beam |
Double beam |
|
Monochromator |
Czerny-Turner type with focal lengths at 350mm |
||
|
Wavelength Range |
190-900nm |
||
|
Grating |
Holographic diffraction grating with 1800 lines/mm |
||
|
Slits |
Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm |
||
|
Wavelength Accuracy |
±0.2 nm |
±0.15 nm |
|
|
Wavelength Repeatability |
±0.1nm |
±0.05nm |
|
|
Lamp Holder |
Automated 8-lamp turret |
||
|
Detector |
Wide range UV sensitive photomultiplier tube |
||
|
Photometric Performance |
Reading Mode |
Transmittance(T), Absorbance(A), Concentration(C) |
|
|
Photometric Range |
0-125%, -0.1-3.00A |
||
|
Static Baseline Drift (Cu) |
≤0.003A/30 min |
≤0.002A/30 min |
|
|
Dynamic Baseline Drift (Cu) |
≤0.005A/15 min |
≤0.004A/15 min |
|
|
Background Correction |
Deuterium (D2) Background Correction and Self-absorption Background Correction |
||
|
Flame Analysis |
Characteristic Concentration |
Cu≤0.035ug/ml |
Cu≤0.02ug/ml |
|
Detection Limit |
Cu≤0.006ug/ml |
Cu≤0.004ug/ml |
|
|
Repeatability (Cu) |
RSD≤0.6% |
RSD≤0.5% |
|
|
Acetylene Flow Control |
Auto 12-level |
Auto 12-level |
|
|
Air Flow Control |
Auto 4-level |
Auto 4-level |
|
|
Nebulizer |
High efficiency glass |
||
|
Burner Adjustment |
Automatic up and down |
||
|
Burner Head |
Titanium alloy 100mm burner for air/acetylene operation |
||
|
Premix Chamber |
Corrosion resistant |
||
|
Safety Protection |
Flame sensor, gas leak sensor, gas pressure sensor |
||
|
Graphite Furnace Analysis |
Characteristic Concentration |
Cd≤0.6pg , Cu≤20pg |
Cd≤0.5pg , Cu≤20pg |
|
Detection Limit |
Cd≤1.0pg , Cu≤25pg |
Cd≤0.8pg , Cu≤25pg |
|
|
Repeatability (Cu) |
RSD≤3% |
RSD≤2.5% |
|
|
Temperature Range |
Ambient -3000℃ |
Ambient -3000℃ |
|
|
Ramp and holding time |
1-255s |
1-255s |
|
|
Heating Rate |
Maximum linear heating rate 2000℃/s |
||
|
Atomization Heating Method |
Light-controlled heating, Time-controlled heating, General heating |
||
|
Gas Flow Rate Inside Tube |
1 L/min |
1 L/min |
|
|
Gas Flow Rate Outside Tube |
4-speed adjustable (0, 50, 200, 250ml/min) |
||
|
Safety Protection |
Water flow sensor, Argon pressure sensor, Furnace body temperature sensor, Graphite tube installation self-inspection. |
||
|
Data Processing |
Software |
RGWIN AAS software package |
|
|
Analytical Method |
Flame AA, Flame AE, Hydride Generation |
||
|
Concentration Calculation Method |
Standard curve(6 linear/non-linear fitting), Standard Addition, Interpolation |
||
|
Repeated Measurement Times |
1-30 times, calculate the average, show SD and RSD value of absorbance and concentration |
||
|
QA/QC Function |
Correlation coefficient, SD & RSD of Abs and calculate SD & RSD of concentration |
||
|
Report Printing |
Parameter printing, resulting printing |
||
|
Communication Port |
Standard RS-232 |
||
|
Others |
Computer |
External(excluded) |
|
|
Dimension & Weight |
850*650*550MM(W*D*H), 100Kg |
||
|
Power Supply |
110/220V, 50/60Hz |
||
|
Working Environment |
Temperature 10 ~ 35 °C, Humidity≦85% |
||
Packing List
|
NO. |
Description |
Qty |
NO. |
Description |
Qty |
|
1 |
Main Unit |
1 |
12 |
Acetylene pressure reducing valve connector |
1 |
|
2 |
Power Cable |
1 |
13 |
5A fuse |
3 |
|
3 |
Data Cable |
1 |
14 |
Argon pressure reducing valve connector |
1 |
|
4 |
Screw Driver |
1 |
15 |
Graphite tube |
5 |
|
5 |
Cu HCL |
1 |
16 |
High power socket |
1 |
|
6 |
Cd HCL |
1 |
17 |
6*4mm argon tube(transparent) |
10m |
|
7 |
Air Compressor |
1 |
18 |
5-50ul pipette |
1 |
|
8 |
6mm acetylene tube(orange) |
10m |
19 |
200ul pipette tip(1000pc/bag) |
1 |
|
9 |
6mm air tube(transparent) |
10m |
20 |
6*10mm cooling water tube |
6m |
|
10 |
USB(manual and software) |
1 |
21 |
Graphite furnace camera connection cable |
1 |
|
11 |
Drain Tube |
2m |
22 |
Ignition filament |
5 |


