High Pressure Ion Chromatograph – Quali-IC™ 180H
HomeStore

High Pressure Ion Chromatograph – Quali-IC™ 180H

High Pressure Ion Chromatograph – Quali-IC™ 180H

$35.00

Original: $100.00

-65%
High Pressure Ion Chromatograph – Quali-IC™ 180H

$100.00

$35.00

The Story

High Pressure Ion Chromatograph – Quali-IC™ 180H

The Quali-IC™ 180H is a high-performance high-pressure ion chromatograph designed for precise, trace-level analysis of inorganic and organic ions under elevated pressure conditions.

  • 45 MPa High-Pressure Pumping System – Enables high-resolution separation and reproducible flow for complex sample matrices.
  • Precision Eluent Generation – Supports accurate isocratic and gradient elution with consistent concentration control.
  • Intelligent System Monitoring – Continuous tracking of pressure, flow, and eluent status ensures safe, stable, and reliable operation.
  • Flexible Method Capabilities – Supports both suppressed and non-suppressed ion chromatography, with optional two-dimensional chromatography configurations.
  • Optimized for Complex Samples – Ideal for environmental, pharmaceutical, chemical, and industrial quality control applications requiring multi-component ion analysis.

This system is engineered to provide exceptional accuracy, method flexibility, and long-term operational reliability for demanding analytical laboratories.

High Pressure Ion Chromatograph – Quali-IC™ 180H Applications

  • Environmental Analysis – Accurate determination of anions and cations in drinking water, wastewater, surface water, and other environmental samples at trace levels.
  • Pharmaceutical Quality Control – Measurement of counter-ions, impurities, and residual inorganic species in drug substances and formulations.
  • Chemical & Petrochemical Testing – Quantitative analysis of ionic species in process chemicals, reagents, and industrial raw materials.
  • Food & Beverage Testing – Assessment of inorganic ions, organic acids, and additives for quality assurance and regulatory compliance.
  • Power & Energy Industries – Monitoring of ionic contaminants in boiler water, cooling water, and other process streams.
  • Research & Advanced Analytics – Supports method development, gradient separations, and complex multi-ion profiling under high-pressure conditions.

Standards for High-Pressure Ion Chromatography (Quali-IC™ 180H)

1. Water and Environmental Monitoring

  • ASTM D2036 – Standard methods for analyzing common anions (chloride, sulfate, nitrate) in water.
  • ASTM D5794 – Determination of inorganic anions in atmospheric deposition samples.
  • ASTM D6832 – Analysis of anions and cations in water for industrial and power generation processes.
  • ASTM D6919 – IC methods for anion determination in water and wastewater.
  • ASTM D7359 – Trace anion measurement using suppressed conductivity IC.
  • ASTM D7994 – Modern IC techniques for inorganic anion analysis in water.
  • US EPA 300.0 / 300.1 – IC methods for fluoride, chloride, nitrate, nitrite, and sulfate in drinking water and wastewater.
  • US EPA 302.0 – Determination of perchlorate in environmental water samples.
  • US EPA 314.0 – Low-concentration perchlorate detection in drinking water.
  • US EPA 321.8 – Determination of bromate, bromide, chlorite, and chlorate in drinking water.
  • US EPA 332.0 – Perchlorate analysis using suppressed conductivity IC.
  • US EPA 1636 – Measurement of inorganic anions in aqueous samples for environmental monitoring.
  • US EPA 6860 – Analysis of organic acids and inorganic anions in water.
  • US EPA 9056 / 9058 – Protocols for inorganic anions in soils, solid waste, and aqueous extracts.
  • DIN 38409-59 & EN 17813 – European standards for inorganic anion measurement in water and wastewater.

2. Combustion Ion Chromatography (Halogens & Sulfur)

  • ASTM D8247 – Analysis of halogens, sulfur, and fluorine in materials using combustion IC.
  • US EPA 1621 – Procedures for total organic fluorine, chlorine, and bromine determination.
  • UOP 991 – Determination of trace halogens and sulfur in petroleum products via combustion IC.

3. Food, Beverage, and Nutritional Analysis (AOAC)

  • AOAC 2001.02 – Nitrate and nitrite determination in foods.
  • AOAC 2012.20 – Inorganic anion analysis in infant formula and nutritional products.
  • AOAC 995.13 – Chloride, nitrate, and sulfate determination in foods.
  • AOAC 996.04 – Analysis of organic acids and inorganic ions in beverages and food products.
  • AOAC 997.08 – Bromide and bromate detection in food and beverage matrices.
  • AOAC 2000.11 – Anion determination in dairy and processed foods.

4. Electronics and Industrial Compliance

  • IEC 62321 – Halogen analysis in electrical and electronic materials for RoHS compliance.
  • IPC-TM-650 2.3.28 – Measurement of ionic contamination on printed circuit boards.

These standards ensure that the Quali-IC™ 180H provides accurate, reliable, and regulatory-compliant ion chromatography results across multiple industries.

High Pressure Ion Chromatograph – Quali-IC™ 180H Key Features

High-Pressure Pumping System
Dual-piston tandem pump capable of pressures up to 45 MPa (6600 psi) with low pulsation and high flow precision for stable and reproducible separations.

High-Pressure Eluent Generator
Built-in generator rated up to 42 MPa, supporting KOH, NaOH, LiOH, and MSA eluents with programmable gradients for automated and reproducible elution.

Advanced Gradient Capability
Nine selectable gradient curves allow flexible separation strategies for complex ion mixtures and method optimization.

Intelligent System Protection
Integrated warning system detects over-pressure, low pressure, and liquid leakage, automatically protecting the instrument and preventing data loss.

Void-Volume-Free High-Pressure Connections
Tool-free connectors minimize dead volume, improving chromatographic efficiency and resolution.

High-Definition Touchscreen Interface
Real-time chromatogram display and system monitoring with one-touch stabilization and easy operational control.

Remote Monitoring & Control
Mobile application support enables remote tracking of instrument status and adjustment of key parameters.

Column Thermostat with Heating & Cooling
Accurate temperature regulation improves retention time stability and method reproducibility.

Suppressor Compatibility
Supports both chemical suppressors and self-regenerating membrane suppressors for flexible detection options.

Two-Dimensional Chromatography Ready
Valve switching with autosampler integration enables advanced multidimensional workflows for complex sample analysis.

This feature set positions the Quali-IC™ 180H as a high-resolution, high-pressure ion chromatography solution for environmental, pharmaceutical, food, chemical, and industrial applications requiring trace-level analysis and robust multi-ion separation.

High Pressure Ion Chromatograph – Quali-IC™ 180H Technical Specifications

Parameter Specification
Model Quali-IC™ 180H
Instrument Type High Pressure Ion Chromatograph
Maximum System Pressure 45 MPa (6600 psi)
Eluent Generator Pressure Rating Up to 42 MPa
Supported Eluents KOH, NaOH, LiOH, MSA
Eluent Concentration Range 0.1–100 mM
Gradient Accuracy ±0.15%
Flow Rate Range 0.001–15 mL/min
Pressure Ripple ≤ 0.5%
Flow Accuracy / Precision ≤ 0.1%
Degassing System Integrated vacuum degasser
Column Thermostat Range 15–80 °C
Temperature Accuracy ±0.1 °C
Suppressor Type Electrolytic micro-membrane suppressor
Detector Auto-range conductivity detector
Detection Range 0–50,000 µS/cm
Baseline Noise ≤ 0.0005 µS/cm
Instrument Linearity ≥ 0.999
Quantitative Repeatability ≤ 0.5%
Voltage 100–240 VAC, 50/60 Hz
Power Consumption 120 W
Dimensions (W × D × H) 380 × 520 × 620 mm
Net Weight 35 kg

Description

High Pressure Ion Chromatograph – Quali-IC™ 180H

The Quali-IC™ 180H is a high-performance high-pressure ion chromatograph designed for precise, trace-level analysis of inorganic and organic ions under elevated pressure conditions.

  • 45 MPa High-Pressure Pumping System – Enables high-resolution separation and reproducible flow for complex sample matrices.
  • Precision Eluent Generation – Supports accurate isocratic and gradient elution with consistent concentration control.
  • Intelligent System Monitoring – Continuous tracking of pressure, flow, and eluent status ensures safe, stable, and reliable operation.
  • Flexible Method Capabilities – Supports both suppressed and non-suppressed ion chromatography, with optional two-dimensional chromatography configurations.
  • Optimized for Complex Samples – Ideal for environmental, pharmaceutical, chemical, and industrial quality control applications requiring multi-component ion analysis.

This system is engineered to provide exceptional accuracy, method flexibility, and long-term operational reliability for demanding analytical laboratories.

High Pressure Ion Chromatograph – Quali-IC™ 180H Applications

  • Environmental Analysis – Accurate determination of anions and cations in drinking water, wastewater, surface water, and other environmental samples at trace levels.
  • Pharmaceutical Quality Control – Measurement of counter-ions, impurities, and residual inorganic species in drug substances and formulations.
  • Chemical & Petrochemical Testing – Quantitative analysis of ionic species in process chemicals, reagents, and industrial raw materials.
  • Food & Beverage Testing – Assessment of inorganic ions, organic acids, and additives for quality assurance and regulatory compliance.
  • Power & Energy Industries – Monitoring of ionic contaminants in boiler water, cooling water, and other process streams.
  • Research & Advanced Analytics – Supports method development, gradient separations, and complex multi-ion profiling under high-pressure conditions.

Standards for High-Pressure Ion Chromatography (Quali-IC™ 180H)

1. Water and Environmental Monitoring

  • ASTM D2036 – Standard methods for analyzing common anions (chloride, sulfate, nitrate) in water.
  • ASTM D5794 – Determination of inorganic anions in atmospheric deposition samples.
  • ASTM D6832 – Analysis of anions and cations in water for industrial and power generation processes.
  • ASTM D6919 – IC methods for anion determination in water and wastewater.
  • ASTM D7359 – Trace anion measurement using suppressed conductivity IC.
  • ASTM D7994 – Modern IC techniques for inorganic anion analysis in water.
  • US EPA 300.0 / 300.1 – IC methods for fluoride, chloride, nitrate, nitrite, and sulfate in drinking water and wastewater.
  • US EPA 302.0 – Determination of perchlorate in environmental water samples.
  • US EPA 314.0 – Low-concentration perchlorate detection in drinking water.
  • US EPA 321.8 – Determination of bromate, bromide, chlorite, and chlorate in drinking water.
  • US EPA 332.0 – Perchlorate analysis using suppressed conductivity IC.
  • US EPA 1636 – Measurement of inorganic anions in aqueous samples for environmental monitoring.
  • US EPA 6860 – Analysis of organic acids and inorganic anions in water.
  • US EPA 9056 / 9058 – Protocols for inorganic anions in soils, solid waste, and aqueous extracts.
  • DIN 38409-59 & EN 17813 – European standards for inorganic anion measurement in water and wastewater.

2. Combustion Ion Chromatography (Halogens & Sulfur)

  • ASTM D8247 – Analysis of halogens, sulfur, and fluorine in materials using combustion IC.
  • US EPA 1621 – Procedures for total organic fluorine, chlorine, and bromine determination.
  • UOP 991 – Determination of trace halogens and sulfur in petroleum products via combustion IC.

3. Food, Beverage, and Nutritional Analysis (AOAC)

  • AOAC 2001.02 – Nitrate and nitrite determination in foods.
  • AOAC 2012.20 – Inorganic anion analysis in infant formula and nutritional products.
  • AOAC 995.13 – Chloride, nitrate, and sulfate determination in foods.
  • AOAC 996.04 – Analysis of organic acids and inorganic ions in beverages and food products.
  • AOAC 997.08 – Bromide and bromate detection in food and beverage matrices.
  • AOAC 2000.11 – Anion determination in dairy and processed foods.

4. Electronics and Industrial Compliance

  • IEC 62321 – Halogen analysis in electrical and electronic materials for RoHS compliance.
  • IPC-TM-650 2.3.28 – Measurement of ionic contamination on printed circuit boards.

These standards ensure that the Quali-IC™ 180H provides accurate, reliable, and regulatory-compliant ion chromatography results across multiple industries.

High Pressure Ion Chromatograph – Quali-IC™ 180H Key Features

High-Pressure Pumping System
Dual-piston tandem pump capable of pressures up to 45 MPa (6600 psi) with low pulsation and high flow precision for stable and reproducible separations.

High-Pressure Eluent Generator
Built-in generator rated up to 42 MPa, supporting KOH, NaOH, LiOH, and MSA eluents with programmable gradients for automated and reproducible elution.

Advanced Gradient Capability
Nine selectable gradient curves allow flexible separation strategies for complex ion mixtures and method optimization.

Intelligent System Protection
Integrated warning system detects over-pressure, low pressure, and liquid leakage, automatically protecting the instrument and preventing data loss.

Void-Volume-Free High-Pressure Connections
Tool-free connectors minimize dead volume, improving chromatographic efficiency and resolution.

High-Definition Touchscreen Interface
Real-time chromatogram display and system monitoring with one-touch stabilization and easy operational control.

Remote Monitoring & Control
Mobile application support enables remote tracking of instrument status and adjustment of key parameters.

Column Thermostat with Heating & Cooling
Accurate temperature regulation improves retention time stability and method reproducibility.

Suppressor Compatibility
Supports both chemical suppressors and self-regenerating membrane suppressors for flexible detection options.

Two-Dimensional Chromatography Ready
Valve switching with autosampler integration enables advanced multidimensional workflows for complex sample analysis.

This feature set positions the Quali-IC™ 180H as a high-resolution, high-pressure ion chromatography solution for environmental, pharmaceutical, food, chemical, and industrial applications requiring trace-level analysis and robust multi-ion separation.

High Pressure Ion Chromatograph – Quali-IC™ 180H Technical Specifications

Parameter Specification
Model Quali-IC™ 180H
Instrument Type High Pressure Ion Chromatograph
Maximum System Pressure 45 MPa (6600 psi)
Eluent Generator Pressure Rating Up to 42 MPa
Supported Eluents KOH, NaOH, LiOH, MSA
Eluent Concentration Range 0.1–100 mM
Gradient Accuracy ±0.15%
Flow Rate Range 0.001–15 mL/min
Pressure Ripple ≤ 0.5%
Flow Accuracy / Precision ≤ 0.1%
Degassing System Integrated vacuum degasser
Column Thermostat Range 15–80 °C
Temperature Accuracy ±0.1 °C
Suppressor Type Electrolytic micro-membrane suppressor
Detector Auto-range conductivity detector
Detection Range 0–50,000 µS/cm
Baseline Noise ≤ 0.0005 µS/cm
Instrument Linearity ≥ 0.999
Quantitative Repeatability ≤ 0.5%
Voltage 100–240 VAC, 50/60 Hz
Power Consumption 120 W
Dimensions (W × D × H) 380 × 520 × 620 mm
Net Weight 35 kg
High Pressure Ion Chromatograph – Quali-IC™ 180H | Qualitest