Ion Chromatograph – Quali-IC™ 200 is an intelligent, high-sensitivity analytical system designed for precise ionic separation and quantification in modern laboratories. Engineered around advanced ion chromatography principles, this platform integrates high-pressure pumping, electrochemical detection, and automated sample handling to deliver accurate, repeatable ion analysis across a wide concentration range.

Designed for IC, HPLC, and UHPLC compatibility, the Quali-IC™ 200 combines a highly sensitive electrochemical detector with flexible operating modes and robust system monitoring. Intelligent safety functions, automated injection options, and modular components make this ion chromatograph suitable for routine quality control, regulatory testing, and advanced analytical research.

Ion Chromatograph – Quali-IC™ 200 (Efficient) Applications

Environmental Testing
Accurate determination of anions and cations in drinking water, wastewater, surface water, and other environmental matrices.

Food & Beverage Analysis
Measurement of inorganic ions, additives, and potential contaminants to ensure quality and regulatory compliance.

Pharmaceutical & Chemical Laboratories
Supports raw material verification, formulation testing, and impurity profiling for quality assurance.

Petrochemical & Industrial Process Control
Monitors ionic species in production streams to maintain process efficiency and product consistency.

Academic & Research Laboratories
Facilitates high-sensitivity ion analysis, method development, and advanced research applications.

The Quali-IC™ 200 is designed for laboratories that require versatile, high-performance ion chromatography capable of handling diverse sample types with reliable, reproducible results.

Ion Chromatography – Quali-IC™ 200: Applicable Standards

The Quali-IC™ 200 follows internationally recognized standards for accurate, reproducible, and compliant ion analysis across multiple industries.

1. Water and Environmental Monitoring

General Anion Analysis (Water and Wastewater):

  • ASTM D2036: Standard testing for common anions (chloride, sulfate, nitrate).
  • ASTM D6832: Analysis of anions and cations in industrial and power-generation water.
  • ASTM D6919: Determination of dissolved inorganic anions in water and wastewater.
  • ASTM D7359: Trace-level anion measurement using suppressed conductivity detection.
  • ASTM D7994: Modern IC techniques for inorganic anion determination.
  • US EPA 300.0 / 300.1: Measurement of fluoride, chloride, nitrate, nitrite, sulfate in drinking water and wastewater.
  • US EPA 1636: Determination of inorganic anions in aqueous samples for environmental monitoring.
  • DIN 38409-59 & EN 17813: European standards for inorganic anion measurement and compliance.

Specialized Contaminants and Matrices:

  • ASTM D5794: Inorganic anions in atmospheric deposition samples (rain, snow).

Perchlorate Detection:

  • US EPA 302.0: General environmental water.
  • US EPA 314.0: Low-concentration perchlorate in drinking water.
  • US EPA 332.0: Suppressed conductivity IC for perchlorate in drinking water.

Disinfection Byproducts:

  • US EPA 321.8: Bromate, bromide, chlorite, chlorate in drinking water.

Organic/Inorganic Mix:

  • US EPA 6860: Analysis of organic acids and inorganic anions in water.

Solid Waste and Soil Matrices:

  • US EPA 9056 / 9058: Inorganic anions in soils, solid waste, and aqueous extracts.

2. Combustion Ion Chromatography (Petrochemicals & Materials)

  • ASTM D8247: Total fluorine, halogens, sulfur via combustion IC.
  • US EPA 1621: Adsorbable organic fluorine, chlorine, and bromine determination.
  • UOP 991: Trace halogens and sulfur analysis in petroleum products.

3. Food, Beverage, and Nutritional Analysis (AOAC)

General Food & Beverage:

  • AOAC 995.13: Chloride, nitrate, sulfate in food matrices.
  • AOAC 996.04: Organic acids and inorganic ions in food and beverages.
  • AOAC 997.08: Bromide and bromate detection in food and drink.
  • AOAC 2000.11: Anion determination in dairy and processed foods.

Specific Nutritional & Safety Concerns:

  • AOAC 2001.02: Nitrate and nitrite quantification in foods.
  • AOAC 2012.20: Inorganic anion analysis in infant formula and nutritional supplements.

4. Electronics and Industrial Compliance

  • IEC 62321: Determination of halogens in electrical and electronic products (RoHS compliance).
  • IPC-TM-650 2.3.28: Measurement of ionic contamination on printed circuit boards (PCBs).

These standards ensure that the Quali-IC™ 200 provides accurate, reproducible, and regulatory-compliant ion analysis across environmental, food, pharmaceutical, chemical, and industrial applications.

Ion Chromatograph – Quali-IC™ 200 (Efficient) Key Features

  • High-Sensitivity Electrochemical Detector
    • Supports DC, pulse, and scan modes for ultra-low detection limits.
    • Enables broad analytical coverage for trace and complex ionic species.
  • Multi-Flow Cell Capability
    • Accommodates up to three flow cells, allowing simultaneous or sequential analyses for different sample types.
  • Advanced Autosampler with Dilution Function
    • Supports micro, partial, and full-loop injection with automatic dilution, enhancing throughput and accuracy.
  • Quad-Pump System
    • Operates up to four separate mobile phases, enabling gradient elution and complex separation workflows.
  • High-Pressure Analytical Pump
    • Delivers stable flow up to 400 bar (5800 psi) with active pulsation compensation, ensuring reproducible chromatography.
  • Intelligent System Monitoring
    • Integrated leak detection, status indicators, and automatic safety interlocks protect both samples and the instrument.
  • Column and Flow Cell Oven
    • Temperature-controlled chamber improves retention time stability and analytical repeatability.
  • Flexible Connectivity and Control
    • Supports LAN, analog, and event-based control, with optional mobile interface for remote monitoring and operation.

The Quali-IC™ 220 is ideal for environmental monitoring, pharmaceutical and chemical QC, food and beverage testing, and advanced research laboratories requiring high-sensitivity, multi-phase, and high-throughput ion analysis.

Ion Chromatograph – Quali-IC™ 200 (Efficient) Technical Specifications

Parameter Specification
Model Quali-IC™ 200
Analytical Technique Ion Chromatography
Detector Type Electrochemical (DC / Pulse / Scan modes)
Detector Current Range 10 pA – 25 mA (mode dependent)
Potential Range -2.50 V to +2.50 V
Noise Level < 2 pA (1 nA range, filter off)
Column Oven Temperature Ambient +7 °C to 60 °C
Pump Type Dual serial piston analytical pump
Maximum Pressure 400 bar / 40 MPa
Flow Rate Range 0.001 – 10 mL/min
Flow Accuracy < 1%
Flow Precision < 0.1% RSD
Autosampler Injection Volume 1 µL – 1000 µL
Injection Precision ≤ 0.5%
Carry-Over ≤ 0.001%
Degasser 4-channel membrane degasser
Communication Interfaces LAN, analog input, event I/O
Voltage 100–240 VAC, 50/60 Hz
Operating Temperature 4–40 °C
Dimensions (W × L × H) 361 × 523 × 208 mm
Weight Approx. 14 kg

Description

Ion Chromatograph – Quali-IC™ 200 (Efficient)

Ion Chromatograph – Quali-IC™ 200 is an intelligent, high-sensitivity analytical system designed for precise ionic separation and quantification in modern laboratories. Engineered around advanced ion chromatography principles, this platform integrates high-pressure pumping, electrochemical detection, and automated sample handling to deliver accurate, repeatable ion analysis across a wide concentration range.

Designed for IC, HPLC, and UHPLC compatibility, the Quali-IC™ 200 combines a highly sensitive electrochemical detector with flexible operating modes and robust system monitoring. Intelligent safety functions, automated injection options, and modular components make this ion chromatograph suitable for routine quality control, regulatory testing, and advanced analytical research.

Ion Chromatograph – Quali-IC™ 200 (Efficient) Applications

Environmental Testing
Accurate determination of anions and cations in drinking water, wastewater, surface water, and other environmental matrices.

Food & Beverage Analysis
Measurement of inorganic ions, additives, and potential contaminants to ensure quality and regulatory compliance.

Pharmaceutical & Chemical Laboratories
Supports raw material verification, formulation testing, and impurity profiling for quality assurance.

Petrochemical & Industrial Process Control
Monitors ionic species in production streams to maintain process efficiency and product consistency.

Academic & Research Laboratories
Facilitates high-sensitivity ion analysis, method development, and advanced research applications.

The Quali-IC™ 200 is designed for laboratories that require versatile, high-performance ion chromatography capable of handling diverse sample types with reliable, reproducible results.

Ion Chromatography – Quali-IC™ 200: Applicable Standards

The Quali-IC™ 200 follows internationally recognized standards for accurate, reproducible, and compliant ion analysis across multiple industries.

1. Water and Environmental Monitoring

General Anion Analysis (Water and Wastewater):

  • ASTM D2036: Standard testing for common anions (chloride, sulfate, nitrate).
  • ASTM D6832: Analysis of anions and cations in industrial and power-generation water.
  • ASTM D6919: Determination of dissolved inorganic anions in water and wastewater.
  • ASTM D7359: Trace-level anion measurement using suppressed conductivity detection.
  • ASTM D7994: Modern IC techniques for inorganic anion determination.
  • US EPA 300.0 / 300.1: Measurement of fluoride, chloride, nitrate, nitrite, sulfate in drinking water and wastewater.
  • US EPA 1636: Determination of inorganic anions in aqueous samples for environmental monitoring.
  • DIN 38409-59 & EN 17813: European standards for inorganic anion measurement and compliance.

Specialized Contaminants and Matrices:

  • ASTM D5794: Inorganic anions in atmospheric deposition samples (rain, snow).

Perchlorate Detection:

  • US EPA 302.0: General environmental water.
  • US EPA 314.0: Low-concentration perchlorate in drinking water.
  • US EPA 332.0: Suppressed conductivity IC for perchlorate in drinking water.

Disinfection Byproducts:

  • US EPA 321.8: Bromate, bromide, chlorite, chlorate in drinking water.

Organic/Inorganic Mix:

  • US EPA 6860: Analysis of organic acids and inorganic anions in water.

Solid Waste and Soil Matrices:

  • US EPA 9056 / 9058: Inorganic anions in soils, solid waste, and aqueous extracts.

2. Combustion Ion Chromatography (Petrochemicals & Materials)

  • ASTM D8247: Total fluorine, halogens, sulfur via combustion IC.
  • US EPA 1621: Adsorbable organic fluorine, chlorine, and bromine determination.
  • UOP 991: Trace halogens and sulfur analysis in petroleum products.

3. Food, Beverage, and Nutritional Analysis (AOAC)

General Food & Beverage:

  • AOAC 995.13: Chloride, nitrate, sulfate in food matrices.
  • AOAC 996.04: Organic acids and inorganic ions in food and beverages.
  • AOAC 997.08: Bromide and bromate detection in food and drink.
  • AOAC 2000.11: Anion determination in dairy and processed foods.

Specific Nutritional & Safety Concerns:

  • AOAC 2001.02: Nitrate and nitrite quantification in foods.
  • AOAC 2012.20: Inorganic anion analysis in infant formula and nutritional supplements.

4. Electronics and Industrial Compliance

  • IEC 62321: Determination of halogens in electrical and electronic products (RoHS compliance).
  • IPC-TM-650 2.3.28: Measurement of ionic contamination on printed circuit boards (PCBs).

These standards ensure that the Quali-IC™ 200 provides accurate, reproducible, and regulatory-compliant ion analysis across environmental, food, pharmaceutical, chemical, and industrial applications.

Ion Chromatograph – Quali-IC™ 200 (Efficient) Key Features

  • High-Sensitivity Electrochemical Detector
    • Supports DC, pulse, and scan modes for ultra-low detection limits.
    • Enables broad analytical coverage for trace and complex ionic species.
  • Multi-Flow Cell Capability
    • Accommodates up to three flow cells, allowing simultaneous or sequential analyses for different sample types.
  • Advanced Autosampler with Dilution Function
    • Supports micro, partial, and full-loop injection with automatic dilution, enhancing throughput and accuracy.
  • Quad-Pump System
    • Operates up to four separate mobile phases, enabling gradient elution and complex separation workflows.
  • High-Pressure Analytical Pump
    • Delivers stable flow up to 400 bar (5800 psi) with active pulsation compensation, ensuring reproducible chromatography.
  • Intelligent System Monitoring
    • Integrated leak detection, status indicators, and automatic safety interlocks protect both samples and the instrument.
  • Column and Flow Cell Oven
    • Temperature-controlled chamber improves retention time stability and analytical repeatability.
  • Flexible Connectivity and Control
    • Supports LAN, analog, and event-based control, with optional mobile interface for remote monitoring and operation.

The Quali-IC™ 220 is ideal for environmental monitoring, pharmaceutical and chemical QC, food and beverage testing, and advanced research laboratories requiring high-sensitivity, multi-phase, and high-throughput ion analysis.

Ion Chromatograph – Quali-IC™ 200 (Efficient) Technical Specifications

Parameter Specification
Model Quali-IC™ 200
Analytical Technique Ion Chromatography
Detector Type Electrochemical (DC / Pulse / Scan modes)
Detector Current Range 10 pA – 25 mA (mode dependent)
Potential Range -2.50 V to +2.50 V
Noise Level < 2 pA (1 nA range, filter off)
Column Oven Temperature Ambient +7 °C to 60 °C
Pump Type Dual serial piston analytical pump
Maximum Pressure 400 bar / 40 MPa
Flow Rate Range 0.001 – 10 mL/min
Flow Accuracy < 1%
Flow Precision < 0.1% RSD
Autosampler Injection Volume 1 µL – 1000 µL
Injection Precision ≤ 0.5%
Carry-Over ≤ 0.001%
Degasser 4-channel membrane degasser
Communication Interfaces LAN, analog input, event I/O
Voltage 100–240 VAC, 50/60 Hz
Operating Temperature 4–40 °C
Dimensions (W × L × H) 361 × 523 × 208 mm
Weight Approx. 14 kg