Original: $100.00
-65%$100.00
$35.00The Story
Ion Chromatograph – Quali-IC™ 500+ (Multi-functional)
The Quali-IC™ 500+ Ion Chromatograph is a high-performance, modular system engineered for precise and adaptable ion analysis across complex laboratory workflows. Leveraging advanced ion chromatography principles, it delivers accurate separation and detection of anions, cations, and polar compounds using conductivity, amperometric, and UV-Vis detection methods.
Featuring a dual-pump, dual-channel architecture, the Quali-IC™ 500+ supports multi-channel expansion, flexible detector setup, and high-pressure operation. Its chemically inert PEEK flow paths, intelligent temperature control, and integrated degassing modules ensure stable baselines, exceptional repeatability, and long-term reliability in demanding analytical environments.
Ion Chromatograph – Quali-IC™ 500+ (Multi-functional) Applications
The Quali-IC™ 500+ Ion Chromatograph is widely applied in the following areas:
Environmental Testing
Analysis of anions and cations in drinking water, wastewater, and surface water for regulatory compliance and environmental monitoring.
Food and Beverage Analysis
Measurement of inorganic ions, preservatives, and additives in a variety of food and beverage products.
Pharmaceutical Quality Control
Support for raw material testing and finished product analysis to ensure product safety and consistency.
Chemical and Petrochemical Laboratories
Monitoring process fluids and detecting impurities in chemical and petrochemical production.
Power and Electronics Industries
Trace-level ionic contamination testing in power systems and electronic components.
Academic and Research Laboratories
Method development, multi-detector experiments, and advanced research requiring flexible, high-precision ion analysis.
Standards for Ion Chromatography (IC)
The following standards provide validated procedures for using ion chromatography across various applications, ensuring precise results and regulatory compliance.
1. Water and Environmental Monitoring
General Anion Analysis (Water and Wastewater)
- ASTM D2036: Determination of common inorganic anions (chloride, sulfate, nitrate).
- ASTM D6832: Analysis of both anions and cations in industrial process and power generation water.
- ASTM D6919: Measurement of dissolved inorganic anions in water and wastewater.
- ASTM D7359: Trace-level anion determination using suppressed conductivity detection.
- ASTM D7994: Modern IC methods for inorganic anion analysis in water.
- US EPA 300.0 / 300.1: Protocols for fluoride, chloride, nitrate, nitrite, and sulfate measurement in drinking water and wastewater.
- US EPA 1636: Broad environmental monitoring of inorganic anions in aqueous samples.
- DIN 38409-59 & EN 17813: European standards for measuring inorganic anions in water and wastewater.
Specialized Contaminants and Matrices
- ASTM D5794: Analysis of inorganic anions in atmospheric deposition (rain, snow).
Perchlorate Detection:
- US EPA 302.0: Perchlorate measurement in environmental water.
- US EPA 314.0: Low-level perchlorate detection in drinking water.
- US EPA 332.0: Suppressed conductivity IC method for perchlorate in drinking water.
Disinfection Byproducts:
- US EPA 321.8: Determination of bromate, bromide, chlorite, and chlorate in drinking water.
Organic/Inorganic Mixed Analysis:
- US EPA 6860: Measurement of organic acids and inorganic anions in water.
Solid Waste and Soil Analysis
- US EPA 9056 / 9058: Analysis of inorganic anions in soil, solid waste, and aqueous extracts.
2. Combustion Ion Chromatography (Petrochemicals and Materials)
- ASTM D8247: Determination of total fluorine, halogens, and sulfur in materials using combustion IC.
- US EPA 1621: Measurement of adsorbable organic fluorine, chlorine, and bromine compounds.
- UOP 991: Determination of trace halogens and sulfur in petroleum products.
3. Food, Beverage, and Nutritional Analysis (AOAC)
General Food and Beverage Analysis
- AOAC 995.13: Measurement of chloride, nitrate, and sulfate across various food matrices.
- AOAC 996.04: Analysis of organic acids and inorganic ions in food and beverages.
- AOAC 997.08: Detection of bromide and bromate in food and drink products.
- AOAC 2000.11: Anion determination in dairy and processed food products.
Nutritional and Safety Testing
- AOAC 2001.02: Quantification of nitrate and nitrite in food.
- AOAC 2012.20: Inorganic anion analysis for infant formula and nutritional supplements.
4. Electronics and Industrial Compliance
- IEC 62321: Determination of halogen content in electrical and electronic products (RoHS compliance).
- IPC-TM-650 2.3.28: Measurement of ionic contamination on printed circuit boards (PCBs).
These standards provide a framework for accurate, repeatable, and compliant ion chromatography across environmental, industrial, food, and electronics applications.
Ion Chromatograph – Quali-IC™ 500+ (Multi-functional) Key Features
- Multi-Detector Compatibility: Supports conductivity, amperometric, and UV-Vis detectors for versatile analytical applications.
- Modular System Architecture: Flexible configuration allows customization and future expansion to meet evolving laboratory needs.
- Dual-Pump, Dual-Channel Design: Expandable up to four analytical channels for simultaneous multi-sample or multi-method operation.
- High-Pressure Quaternary Pump: Provides stable flow with minimal pulsation, ensuring reliable separations.
- Integrated Vacuum Degasser: Enhances baseline stability and improves repeatability of analytical results.
- Built-In Eluent Generator: Supports KOH, NaOH, LiOH, and MSA eluents for consistent, high-purity mobile phase preparation.
- Chemically Inert PEEK Flow Paths: Compatible with aqueous eluents across a pH range of 0–14, preserving sample integrity.
- Dual-Terminal Control: Operates via PC or tablet (PAD) for flexible laboratory workflow management.
- Ultrasonic Liquid-Level Monitoring: Provides real-time tracking of water usage and remaining run-time for uninterrupted operation.
- Advanced Temperature-Controlled Column Compartment: Ensures reproducible separations across multiple runs and applications.
Ion Chromatograph – Quali-IC™ 500+ (Multi-functional) Technical Specifications
| Parameter | Specification |
|---|---|
| Instrument Type | Ion Chromatograph |
| Model | Quali-IC™ 500+ |
| Detector Options | Conductivity, Amperometric, UV-Vis |
| Conductivity Detector Range | 0–50,000 µS/cm |
| Conductivity Resolution | ≤ 0.0020 nS/cm |
| UV-Vis Wavelength Range | 190–740 nm |
| Amperometric Signal Range | 10 pA–200 µA |
| Minimum Detectable Concentration | Cl⁻ ≤ 0.0001 µg/mL; Li⁺ ≤ 0.0001 µg/mL |
| Pump Type | High-pressure dual-piston quaternary pump |
| Maximum Pump Pressure | 42 MPa |
| Flow Rate Range | 0.001–12 mL/min |
| Flow Stability | ≤ 0.2% |
| Pressure Ripple | ≤ 0.5% |
| Autosampler Capacity | 120 × 2 mL (standard) |
| Injection Volume | 1 µL minimum |
| Eluent Generator | KOH / NaOH / LiOH / MSA |
| Eluent Concentration Range | 0.1–100 mM |
| Degasser | Integrated vacuum degasser |
| Column Temperature Range | Ambient +5 °C to 60 °C |
| Temperature Accuracy | ±0.1 °C |
| Suppressor | Self-regenerating electrolytic micro-membrane |
| Supported Column Sizes | 2, 3, 4, and 5 mm I.D. |
| Flow Path Material | Metal-free PEEK |
| Operating Environment | Laboratory use |
Description
Ion Chromatograph – Quali-IC™ 500+ (Multi-functional)
The Quali-IC™ 500+ Ion Chromatograph is a high-performance, modular system engineered for precise and adaptable ion analysis across complex laboratory workflows. Leveraging advanced ion chromatography principles, it delivers accurate separation and detection of anions, cations, and polar compounds using conductivity, amperometric, and UV-Vis detection methods.
Featuring a dual-pump, dual-channel architecture, the Quali-IC™ 500+ supports multi-channel expansion, flexible detector setup, and high-pressure operation. Its chemically inert PEEK flow paths, intelligent temperature control, and integrated degassing modules ensure stable baselines, exceptional repeatability, and long-term reliability in demanding analytical environments.
Ion Chromatograph – Quali-IC™ 500+ (Multi-functional) Applications
The Quali-IC™ 500+ Ion Chromatograph is widely applied in the following areas:
Environmental Testing
Analysis of anions and cations in drinking water, wastewater, and surface water for regulatory compliance and environmental monitoring.
Food and Beverage Analysis
Measurement of inorganic ions, preservatives, and additives in a variety of food and beverage products.
Pharmaceutical Quality Control
Support for raw material testing and finished product analysis to ensure product safety and consistency.
Chemical and Petrochemical Laboratories
Monitoring process fluids and detecting impurities in chemical and petrochemical production.
Power and Electronics Industries
Trace-level ionic contamination testing in power systems and electronic components.
Academic and Research Laboratories
Method development, multi-detector experiments, and advanced research requiring flexible, high-precision ion analysis.
Standards for Ion Chromatography (IC)
The following standards provide validated procedures for using ion chromatography across various applications, ensuring precise results and regulatory compliance.
1. Water and Environmental Monitoring
General Anion Analysis (Water and Wastewater)
- ASTM D2036: Determination of common inorganic anions (chloride, sulfate, nitrate).
- ASTM D6832: Analysis of both anions and cations in industrial process and power generation water.
- ASTM D6919: Measurement of dissolved inorganic anions in water and wastewater.
- ASTM D7359: Trace-level anion determination using suppressed conductivity detection.
- ASTM D7994: Modern IC methods for inorganic anion analysis in water.
- US EPA 300.0 / 300.1: Protocols for fluoride, chloride, nitrate, nitrite, and sulfate measurement in drinking water and wastewater.
- US EPA 1636: Broad environmental monitoring of inorganic anions in aqueous samples.
- DIN 38409-59 & EN 17813: European standards for measuring inorganic anions in water and wastewater.
Specialized Contaminants and Matrices
- ASTM D5794: Analysis of inorganic anions in atmospheric deposition (rain, snow).
Perchlorate Detection:
- US EPA 302.0: Perchlorate measurement in environmental water.
- US EPA 314.0: Low-level perchlorate detection in drinking water.
- US EPA 332.0: Suppressed conductivity IC method for perchlorate in drinking water.
Disinfection Byproducts:
- US EPA 321.8: Determination of bromate, bromide, chlorite, and chlorate in drinking water.
Organic/Inorganic Mixed Analysis:
- US EPA 6860: Measurement of organic acids and inorganic anions in water.
Solid Waste and Soil Analysis
- US EPA 9056 / 9058: Analysis of inorganic anions in soil, solid waste, and aqueous extracts.
2. Combustion Ion Chromatography (Petrochemicals and Materials)
- ASTM D8247: Determination of total fluorine, halogens, and sulfur in materials using combustion IC.
- US EPA 1621: Measurement of adsorbable organic fluorine, chlorine, and bromine compounds.
- UOP 991: Determination of trace halogens and sulfur in petroleum products.
3. Food, Beverage, and Nutritional Analysis (AOAC)
General Food and Beverage Analysis
- AOAC 995.13: Measurement of chloride, nitrate, and sulfate across various food matrices.
- AOAC 996.04: Analysis of organic acids and inorganic ions in food and beverages.
- AOAC 997.08: Detection of bromide and bromate in food and drink products.
- AOAC 2000.11: Anion determination in dairy and processed food products.
Nutritional and Safety Testing
- AOAC 2001.02: Quantification of nitrate and nitrite in food.
- AOAC 2012.20: Inorganic anion analysis for infant formula and nutritional supplements.
4. Electronics and Industrial Compliance
- IEC 62321: Determination of halogen content in electrical and electronic products (RoHS compliance).
- IPC-TM-650 2.3.28: Measurement of ionic contamination on printed circuit boards (PCBs).
These standards provide a framework for accurate, repeatable, and compliant ion chromatography across environmental, industrial, food, and electronics applications.
Ion Chromatograph – Quali-IC™ 500+ (Multi-functional) Key Features
- Multi-Detector Compatibility: Supports conductivity, amperometric, and UV-Vis detectors for versatile analytical applications.
- Modular System Architecture: Flexible configuration allows customization and future expansion to meet evolving laboratory needs.
- Dual-Pump, Dual-Channel Design: Expandable up to four analytical channels for simultaneous multi-sample or multi-method operation.
- High-Pressure Quaternary Pump: Provides stable flow with minimal pulsation, ensuring reliable separations.
- Integrated Vacuum Degasser: Enhances baseline stability and improves repeatability of analytical results.
- Built-In Eluent Generator: Supports KOH, NaOH, LiOH, and MSA eluents for consistent, high-purity mobile phase preparation.
- Chemically Inert PEEK Flow Paths: Compatible with aqueous eluents across a pH range of 0–14, preserving sample integrity.
- Dual-Terminal Control: Operates via PC or tablet (PAD) for flexible laboratory workflow management.
- Ultrasonic Liquid-Level Monitoring: Provides real-time tracking of water usage and remaining run-time for uninterrupted operation.
- Advanced Temperature-Controlled Column Compartment: Ensures reproducible separations across multiple runs and applications.
Ion Chromatograph – Quali-IC™ 500+ (Multi-functional) Technical Specifications
| Parameter | Specification |
|---|---|
| Instrument Type | Ion Chromatograph |
| Model | Quali-IC™ 500+ |
| Detector Options | Conductivity, Amperometric, UV-Vis |
| Conductivity Detector Range | 0–50,000 µS/cm |
| Conductivity Resolution | ≤ 0.0020 nS/cm |
| UV-Vis Wavelength Range | 190–740 nm |
| Amperometric Signal Range | 10 pA–200 µA |
| Minimum Detectable Concentration | Cl⁻ ≤ 0.0001 µg/mL; Li⁺ ≤ 0.0001 µg/mL |
| Pump Type | High-pressure dual-piston quaternary pump |
| Maximum Pump Pressure | 42 MPa |
| Flow Rate Range | 0.001–12 mL/min |
| Flow Stability | ≤ 0.2% |
| Pressure Ripple | ≤ 0.5% |
| Autosampler Capacity | 120 × 2 mL (standard) |
| Injection Volume | 1 µL minimum |
| Eluent Generator | KOH / NaOH / LiOH / MSA |
| Eluent Concentration Range | 0.1–100 mM |
| Degasser | Integrated vacuum degasser |
| Column Temperature Range | Ambient +5 °C to 60 °C |
| Temperature Accuracy | ±0.1 °C |
| Suppressor | Self-regenerating electrolytic micro-membrane |
| Supported Column Sizes | 2, 3, 4, and 5 mm I.D. |
| Flow Path Material | Metal-free PEEK |
| Operating Environment | Laboratory use |