Ion Chromatograph – Quali-IC™ 300+
HomeStore

Ion Chromatograph – Quali-IC™ 300+

Ion Chromatograph – Quali-IC™ 300+

$35.00

Original: $100.00

-65%
Ion Chromatograph – Quali-IC™ 300+

$100.00

$35.00

The Story

Ion Chromatograph – Quali-IC™ 300+

The Quali-IC™ 300+ is a next-generation dual-channel ion chromatograph designed for laboratories requiring high-efficiency, high-accuracy ion analysis. Its fully independent anion and cation channels allow simultaneous detection without cross-interference, boosting throughput and workflow efficiency.

Dual Independent Channels
Allows simultaneous anion and cation analysis with no mutual interference, improving productivity.

Advanced Eluent Generation Platform
Supports precise, programmable generation of hydroxide or methanesulfonic acid eluents for isocratic and gradient separations.

High-Pressure Pump Architecture
Ensures stable flow, accurate gradient delivery, and reproducible chromatographic performance.

Precision Conductivity Detection
Provides ultra-low detection limits, wide dynamic range (ppb to ppm), and stable baselines for accurate quantification.

Integrated Touchscreen Control
Real-time system visualization, parameter control, and workflow management directly from the instrument.

Intelligent Safety Monitoring
Includes liquid leakage detection, pressure alarms, and automatic shutdown to protect both the instrument and operator.

Optional Automation Features
High-precision autosampler and valve switching options enable unattended operation and advanced analytical workflows.

The Quali-IC™ 300+ is ideal for environmental, pharmaceutical, food, chemical, and research laboratories, offering both routine analysis reliability and advanced multi-ion separation capabilities.

Ion Chromatograph – Quali-IC™ 300+ Applications

The Quali-IC™ 300+ is widely used for accurate and reliable anion and cation analysis across multiple industries and laboratory settings:

Environmental Monitoring
Determination of inorganic anions and cations in drinking water, wastewater, surface water, and environmental samples.

Food & Beverage Testing
Analysis of preservatives, additives, organic acids, and ionic contaminants in food products and beverages.

Pharmaceutical & Biotechnology Laboratories
Quality control and impurity analysis of raw materials, intermediates, and finished products.

Chemical & Industrial Analysis
Monitoring ionic species in chemicals, process streams, and industrial materials.

Energy & Power Industry
Ion analysis in boiler water, cooling water, and power plant process systems.

Academic & Research Laboratories
Method development, multi-component ion separation studies, and advanced analytical research.

Standards for Ion Chromatography (IC) – Quali-IC™ 300+

This list outlines standardized methods applicable to IC across environmental, industrial, food, and electronics laboratories:

1. Water and Environmental Analysis (ASTM & US EPA)

General Anion Analysis

  • ASTM D2036: Standard test methods for analyzing chloride, sulfate, and nitrate in water.
  • ASTM D6832: Analysis of anions and cations in water used in power generation and industrial processes.
  • ASTM D6919: Methods for determining anions in water and wastewater.
  • ASTM D7359: Procedures for measuring trace anions using suppressed conductivity IC.
  • ASTM D7994: Modern IC techniques for inorganic anion determination.
  • US EPA 300.0 / 300.1: Measurement of inorganic anions (fluoride, chloride, nitrate, nitrite, sulfate) in drinking water and wastewater.
  • US EPA 1636: Determination of inorganic anions in aqueous samples for environmental monitoring programs.
  • DIN 38409-59 & EN 17813: European standards for measuring inorganic anions in water and wastewater for compliance.

Specialized Contaminants

  • ASTM D5794: IC determination of inorganic anions in atmospheric deposition (rain/snow) samples.
  • US EPA 302.0: Detection of perchlorate in environmental water samples.
  • US EPA 314.0: Low-concentration perchlorate detection in drinking water.
  • US EPA 332.0: Perchlorate analysis using suppressed conductivity IC.
  • US EPA 321.8: Determination of bromate, bromide, chlorite, and chlorate in drinking water.
  • US EPA 6860: Analysis of organic acids and inorganic anions in water.
  • US EPA 9056 / 9058: Protocols for inorganic anions in soils, solid waste, and aqueous extracts.

2. Combustion Ion Chromatography (Halogens & Sulfur)

  • ASTM D8247: Determination of halogens, sulfur, and fluorine via combustion IC.
  • US EPA 1621: Procedures for measuring adsorbable organic fluorine, chlorine, and bromine.
  • UOP 991: Analysis of total halogens and sulfur in petroleum products.

3. Food, Beverage, and Nutritional Analysis (AOAC)

General Food & Beverage

  • AOAC 995.13: Measurement of chloride, nitrate, and sulfate in food matrices.
  • AOAC 996.04: Analysis of organic acids and inorganic ions in beverages and food products.
  • AOAC 997.08: Detection of bromide and bromate in food and drink.
  • AOAC 2000.11: Anion determination for dairy and processed foods.

Specific Nutritional Analysis

  • AOAC 2001.02: Quantification of nitrate and nitrite in foods.
  • AOAC 2012.20: Inorganic anion analysis for infant formula and nutritional supplements.

4. Electronics and Industrial Compliance

  • IEC 62321: Determination of halogens in electrical/electronic products (RoHS compliance).
  • IPC-TM-650 2.3.28: Measuring ionic contamination on printed circuit boards.

This comprehensive standards coverage ensures that the Quali-IC™ 300+ meets regulatory and quality requirements across diverse applications.

Ion Chromatograph – Quali-IC™ 300+ Key Features

The Quali-IC™ 400+ is an advanced, intelligent dual-channel ion chromatograph designed for high-throughput, high-precision ion analysis in modern analytical laboratories. Built around independent anion and cation channels, this system allows simultaneous operation without mutual interference, significantly improving workflow efficiency and laboratory productivity.

  • True Dual-Channel Architecture – Independent anion and cation channels operate simultaneously with no cross-interference.
  • Built-In Dual-Membrane Eluent Generator – Produces precise eluents using only pure water, eliminating the need for degassing tubing and capture columns; supports pressures up to 30 MPa.
  • High-Pressure, Metal-Free Flow Path – PEEK pump heads and tubing provide chemical inertness across pH 0–14 and compatibility with reversed-phase solvents.
  • Ultra-Pure Online Ion Purification – Reduces baseline noise, improves signal-to-noise ratio, and lowers water quality requirements.
  • Advanced Degassing & Gas–Liquid Separation – Integrated gas-liquid separator and continuous vacuum degasser ensure stable flow and consistent detector response.
  • Precision Conductivity Detection – Digital, temperature-controlled conductivity cell delivers ultra-low noise and high linearity from ppb to ppm levels.
  • Integrated Heating & Thermal Insulation System – Multi-point temperature control stabilizes columns, suppressors, and detectors for reproducible results.
  • Comprehensive Safety Monitoring – Built-in alarms for leakage, pressure, eluent consumption, and system faults enhance operational safety.
  • 10-Inch HD Touchscreen Interface – Real-time flow path visualization and instrument control for intuitive operation.
  • Optional Dual-Channel Autosampler – Enables unattended operation with high injection repeatability for both anion and cation channels.
  • Mobile App Connectivity – Remote monitoring and control via smartphone for operational flexibility.

Ion Chromatograph – Quali-IC™ 300+ Technical Specifications

Parameter Specification
Model Quali-IC™ 300+
System Type Dual-channel Ion Chromatograph
Pump Type Two-stage peristaltic + piston pump
Maximum Pressure 42 MPa
Flow Rate Range 0.001–12 mL/min
Flow Accuracy ≤±0.07%
Flow Stability ≤0.09%
Pressure Display Accuracy ≤0.1 MPa
Conductivity Cell Volume ≤0.4 µL
Conductivity Range 0–50,000 µS/cm
Resolution 0.0020 nS/cm
Baseline Noise ≤0.0002 µS/cm
Baseline Drift ≤0.001 µS / 30 min
Linearity ≥0.999
Repeatability (Qualitative) ≤0.05%
Repeatability (Quantitative) ≤0.06%
Suppressor Type Self-regenerating micro-membrane
Suppression Capacity 200 µeq/min (anion), 100 µeq/min (cation)
Eluent Types KOH, NaOH, LiOH, MSA
Eluent Concentration Range 0.1–100 mM
Column Temperature Range Ambient +5 to 60 °C
Temperature Stability ≤0.1 °C/h
Degassing Efficiency ≥90% at 1.0 mL/min
Display 10-inch HD LCD touch screen
Power Consumption 320 W
Dimensions (W × D × H) 580 × 487 × 635 mm
Weight 52 kg
Optional Accessories Dual-channel autosampler, mobile app

Description

Ion Chromatograph – Quali-IC™ 300+

The Quali-IC™ 300+ is a next-generation dual-channel ion chromatograph designed for laboratories requiring high-efficiency, high-accuracy ion analysis. Its fully independent anion and cation channels allow simultaneous detection without cross-interference, boosting throughput and workflow efficiency.

Dual Independent Channels
Allows simultaneous anion and cation analysis with no mutual interference, improving productivity.

Advanced Eluent Generation Platform
Supports precise, programmable generation of hydroxide or methanesulfonic acid eluents for isocratic and gradient separations.

High-Pressure Pump Architecture
Ensures stable flow, accurate gradient delivery, and reproducible chromatographic performance.

Precision Conductivity Detection
Provides ultra-low detection limits, wide dynamic range (ppb to ppm), and stable baselines for accurate quantification.

Integrated Touchscreen Control
Real-time system visualization, parameter control, and workflow management directly from the instrument.

Intelligent Safety Monitoring
Includes liquid leakage detection, pressure alarms, and automatic shutdown to protect both the instrument and operator.

Optional Automation Features
High-precision autosampler and valve switching options enable unattended operation and advanced analytical workflows.

The Quali-IC™ 300+ is ideal for environmental, pharmaceutical, food, chemical, and research laboratories, offering both routine analysis reliability and advanced multi-ion separation capabilities.

Ion Chromatograph – Quali-IC™ 300+ Applications

The Quali-IC™ 300+ is widely used for accurate and reliable anion and cation analysis across multiple industries and laboratory settings:

Environmental Monitoring
Determination of inorganic anions and cations in drinking water, wastewater, surface water, and environmental samples.

Food & Beverage Testing
Analysis of preservatives, additives, organic acids, and ionic contaminants in food products and beverages.

Pharmaceutical & Biotechnology Laboratories
Quality control and impurity analysis of raw materials, intermediates, and finished products.

Chemical & Industrial Analysis
Monitoring ionic species in chemicals, process streams, and industrial materials.

Energy & Power Industry
Ion analysis in boiler water, cooling water, and power plant process systems.

Academic & Research Laboratories
Method development, multi-component ion separation studies, and advanced analytical research.

Standards for Ion Chromatography (IC) – Quali-IC™ 300+

This list outlines standardized methods applicable to IC across environmental, industrial, food, and electronics laboratories:

1. Water and Environmental Analysis (ASTM & US EPA)

General Anion Analysis

  • ASTM D2036: Standard test methods for analyzing chloride, sulfate, and nitrate in water.
  • ASTM D6832: Analysis of anions and cations in water used in power generation and industrial processes.
  • ASTM D6919: Methods for determining anions in water and wastewater.
  • ASTM D7359: Procedures for measuring trace anions using suppressed conductivity IC.
  • ASTM D7994: Modern IC techniques for inorganic anion determination.
  • US EPA 300.0 / 300.1: Measurement of inorganic anions (fluoride, chloride, nitrate, nitrite, sulfate) in drinking water and wastewater.
  • US EPA 1636: Determination of inorganic anions in aqueous samples for environmental monitoring programs.
  • DIN 38409-59 & EN 17813: European standards for measuring inorganic anions in water and wastewater for compliance.

Specialized Contaminants

  • ASTM D5794: IC determination of inorganic anions in atmospheric deposition (rain/snow) samples.
  • US EPA 302.0: Detection of perchlorate in environmental water samples.
  • US EPA 314.0: Low-concentration perchlorate detection in drinking water.
  • US EPA 332.0: Perchlorate analysis using suppressed conductivity IC.
  • US EPA 321.8: Determination of bromate, bromide, chlorite, and chlorate in drinking water.
  • US EPA 6860: Analysis of organic acids and inorganic anions in water.
  • US EPA 9056 / 9058: Protocols for inorganic anions in soils, solid waste, and aqueous extracts.

2. Combustion Ion Chromatography (Halogens & Sulfur)

  • ASTM D8247: Determination of halogens, sulfur, and fluorine via combustion IC.
  • US EPA 1621: Procedures for measuring adsorbable organic fluorine, chlorine, and bromine.
  • UOP 991: Analysis of total halogens and sulfur in petroleum products.

3. Food, Beverage, and Nutritional Analysis (AOAC)

General Food & Beverage

  • AOAC 995.13: Measurement of chloride, nitrate, and sulfate in food matrices.
  • AOAC 996.04: Analysis of organic acids and inorganic ions in beverages and food products.
  • AOAC 997.08: Detection of bromide and bromate in food and drink.
  • AOAC 2000.11: Anion determination for dairy and processed foods.

Specific Nutritional Analysis

  • AOAC 2001.02: Quantification of nitrate and nitrite in foods.
  • AOAC 2012.20: Inorganic anion analysis for infant formula and nutritional supplements.

4. Electronics and Industrial Compliance

  • IEC 62321: Determination of halogens in electrical/electronic products (RoHS compliance).
  • IPC-TM-650 2.3.28: Measuring ionic contamination on printed circuit boards.

This comprehensive standards coverage ensures that the Quali-IC™ 300+ meets regulatory and quality requirements across diverse applications.

Ion Chromatograph – Quali-IC™ 300+ Key Features

The Quali-IC™ 400+ is an advanced, intelligent dual-channel ion chromatograph designed for high-throughput, high-precision ion analysis in modern analytical laboratories. Built around independent anion and cation channels, this system allows simultaneous operation without mutual interference, significantly improving workflow efficiency and laboratory productivity.

  • True Dual-Channel Architecture – Independent anion and cation channels operate simultaneously with no cross-interference.
  • Built-In Dual-Membrane Eluent Generator – Produces precise eluents using only pure water, eliminating the need for degassing tubing and capture columns; supports pressures up to 30 MPa.
  • High-Pressure, Metal-Free Flow Path – PEEK pump heads and tubing provide chemical inertness across pH 0–14 and compatibility with reversed-phase solvents.
  • Ultra-Pure Online Ion Purification – Reduces baseline noise, improves signal-to-noise ratio, and lowers water quality requirements.
  • Advanced Degassing & Gas–Liquid Separation – Integrated gas-liquid separator and continuous vacuum degasser ensure stable flow and consistent detector response.
  • Precision Conductivity Detection – Digital, temperature-controlled conductivity cell delivers ultra-low noise and high linearity from ppb to ppm levels.
  • Integrated Heating & Thermal Insulation System – Multi-point temperature control stabilizes columns, suppressors, and detectors for reproducible results.
  • Comprehensive Safety Monitoring – Built-in alarms for leakage, pressure, eluent consumption, and system faults enhance operational safety.
  • 10-Inch HD Touchscreen Interface – Real-time flow path visualization and instrument control for intuitive operation.
  • Optional Dual-Channel Autosampler – Enables unattended operation with high injection repeatability for both anion and cation channels.
  • Mobile App Connectivity – Remote monitoring and control via smartphone for operational flexibility.

Ion Chromatograph – Quali-IC™ 300+ Technical Specifications

Parameter Specification
Model Quali-IC™ 300+
System Type Dual-channel Ion Chromatograph
Pump Type Two-stage peristaltic + piston pump
Maximum Pressure 42 MPa
Flow Rate Range 0.001–12 mL/min
Flow Accuracy ≤±0.07%
Flow Stability ≤0.09%
Pressure Display Accuracy ≤0.1 MPa
Conductivity Cell Volume ≤0.4 µL
Conductivity Range 0–50,000 µS/cm
Resolution 0.0020 nS/cm
Baseline Noise ≤0.0002 µS/cm
Baseline Drift ≤0.001 µS / 30 min
Linearity ≥0.999
Repeatability (Qualitative) ≤0.05%
Repeatability (Quantitative) ≤0.06%
Suppressor Type Self-regenerating micro-membrane
Suppression Capacity 200 µeq/min (anion), 100 µeq/min (cation)
Eluent Types KOH, NaOH, LiOH, MSA
Eluent Concentration Range 0.1–100 mM
Column Temperature Range Ambient +5 to 60 °C
Temperature Stability ≤0.1 °C/h
Degassing Efficiency ≥90% at 1.0 mL/min
Display 10-inch HD LCD touch screen
Power Consumption 320 W
Dimensions (W × D × H) 580 × 487 × 635 mm
Weight 52 kg
Optional Accessories Dual-channel autosampler, mobile app
Ion Chromatograph – Quali-IC™ 300+ | Qualitest