Original: $100.00
-65%$100.00
$35.00The Story
Portable Ion Chromatograph – Quali-IC™ 80
The Quali-IC™ 80 Portable Ion Chromatograph is a compact, self-contained ion chromatography system built for field and on-site testing where full-scale laboratory instruments are not feasible. Designed for mobility without sacrificing performance, it integrates advanced analytical capability, rugged housing, and battery-powered functionality into one streamlined unit.
Equipped with conductivity detection, the system separates and measures anions and cations at trace levels, delivering dependable results across concentrations ranging from parts per billion (ppb) to parts per million (ppm). Metal-free PEEK flow paths help maintain chemical compatibility and sample integrity, while automatic signal range adjustment and stable pumping control ensure consistent, high-quality data. The Quali-IC™ 80 brings reliable, laboratory-level ion analysis directly to the point of sampling.
Portable Ion Chromatograph – Quali-IC™ 80 Applications
Environmental Monitoring
On-site measurement of anions and cations in surface water, groundwater, and wastewater, eliminating delays associated with sample transport to a central laboratory.
Drinking Water and Utilities
Rapid field verification of ionic contaminants and regulatory compliance parameters in municipal and potable water systems.
Industrial Process Monitoring
Real-time ion measurement in process fluids, cooling water systems, and chemical solutions to support quality control and operational efficiency.
Emergency and Mobile Laboratories
Portable ion chromatography for field investigations, spill response, environmental incidents, and mobile testing operations.
Research and Education
Practical ion chromatography analysis for academic instruction, demonstrations, and applied research where portability and straightforward operation are essential.
Standards
The following standards define the proper use of ion chromatography (IC) across multiple applications to ensure accurate results and regulatory compliance.
1. Water and Environmental Monitoring
General Anion Analysis (Water and Wastewater)
- ASTM D2036: Determination of common inorganic anions such as chloride, sulfate, and nitrate in water.
- ASTM D6832: Measurement of both anions and cations in water, particularly for industrial systems and power generation.
- ASTM D6919: Analysis of dissolved inorganic anions in water and wastewater.
- ASTM D7359: Measurement of trace-level anions in water using suppressed conductivity detection.
- ASTM D7994: Determination of inorganic anions using advanced ion chromatography techniques.
- US EPA 300.0 / 300.1: Measurement of inorganic anions, including fluoride, chloride, nitrate, nitrite, and sulfate, in drinking water and wastewater.
- US EPA 1636: Determination of inorganic anions in aqueous samples for environmental monitoring.
- DIN 38409-59 and EN 17813: European standards for measuring inorganic anions in water and wastewater.
Specialized Contaminants and Sample Types
- ASTM D5794: Measurement of inorganic anions in atmospheric deposition, including rain and snow.
Perchlorate Analysis (Environmental and Drinking Water):
- US EPA 302.0: Measurement of perchlorate in environmental water samples.
- US EPA 314.0: Detection of low-level perchlorate in drinking water.
- US EPA 332.0: Measurement of perchlorate in drinking water using suppressed conductivity detection.
Disinfection Byproducts:
- US EPA 321.8: Measurement of bromate, bromide, chlorite, and chlorate in drinking water.
Mixed Organic and Inorganic Analysis:
- US EPA 6860: Measurement of organic acids and inorganic anions in water samples.
Solid Waste and Soil Analysis
- US EPA 9056 / 9058: Determination of inorganic anions in soil, solid waste, and aqueous extracts.
2. Combustion Ion Chromatography (Petrochemicals and Materials)
- ASTM D8247: Determination of total fluorine, halogens, and sulfur in various materials using combustion ion chromatography.
- US EPA 1621: Measurement of adsorbable organic fluorine, chlorine, and bromine compounds.
- UOP 991: Determination of trace halogens and sulfur in petroleum products.
3. Food, Beverage, and Nutritional Analysis (AOAC)
General Food and Beverage Testing
- AOAC 995.13: Measurement of chloride, nitrate, and sulfate in food products.
- AOAC 996.04: Analysis of organic acids and inorganic ions in food and beverages.
- AOAC 997.08: Measurement of bromide and bromate in food and beverage samples.
- AOAC 2000.11: Determination of anions in dairy and processed food products.
Nutritional and Safety Analysis
- AOAC 2001.02: Measurement of nitrate and nitrite levels in food products.
- AOAC 2012.20: Determination of inorganic anions in infant formula and nutritional supplements.
4. Electronics and Industrial Compliance
- IEC 62321: Determination of halogen content in electrical and electronic products to support RoHS compliance.
- IPC-TM-650 2.3.28: Measurement of ionic contamination on printed circuit boards (PCBs).
These standards provide validated procedures for ion chromatography across environmental, industrial, food, pharmaceutical, and electronics applications, supporting reliable analysis and regulatory compliance.
Portable Ion Chromatograph – Quali-IC™ 80 Key Features
True Portable Ion Chromatograph Design
Compact, lightweight enclosure designed specifically for outdoor and on-site ion chromatography, allowing convenient transport and reliable operation in field environments.
Dual Power Operation
Supports both 220V AC power and an integrated lithium battery, ensuring continuous analysis whether operating in the laboratory or in remote locations.
Metal-Free Flow Path
Chemically inert PEEK flow system compatible with aqueous eluents across a pH range of 0–14, as well as reversed-phase solvents, helping maintain sample integrity and broad chemical compatibility.
Auto-Range Conductivity Detection
Automatically adjusts the detection range to support accurate ion measurement from parts per billion (ppb) to parts per million (ppm) concentrations.
Uninterruptible Power Supply (UPS)
Allows battery replacement without interrupting instrument operation, helping protect ongoing analysis and preserving data continuity.
Water–Electricity Separation Design
Separates fluid pathways from electrical components to reduce the risk of circuit damage caused by eluent leaks during field operation.
User-Friendly Operation
Includes a Bluetooth keyboard and mouse for convenient system control, simplifying setup and operation in both laboratory and field settings.
Portable Ion Chromatograph – Quali-IC™ 80 Technical Specifications
| Parameter | Specification |
|---|---|
| Instrument Type | Portable Ion Chromatograph |
| Pump Type | Dual-piston serial pump |
| Maximum Pump Pressure | 42 MPa |
| Flow Rate Range | 0.001 – 12 mL/min |
| Flow Stability | ≤ 0.67% |
| Flow Path Material | Metal-free PEEK |
| Supported Column Sizes | 2, 3, 4, and 5 mm I.D. |
| Maximum Column Length | 250 mm analytical + 50 mm guard |
| Suppressor Type | Self-regenerating electrolytic micro-membrane |
| Detection Method | Auto-range conductivity detector |
| Detector Cell Volume | ≤ 0.8 µL |
| Detection Range | 0 – 45,000 µS/cm |
| Resolution | ≤ 0.0020 nS/cm |
| Linearity | ≥ 0.999 |
| Quantitative Repeatability | ≤ 0.71% |
| Qualitative Repeatability | ≤ 0.07% |
| Minimum Detectable Concentration | Cl⁻ ≤ 0.0012 µg/mL; Li⁺ ≤ 0.0012 µg/mL |
| Column Heater Range | Ambient +5 °C to 60 °C |
| Temperature Accuracy | ±0.2 °C |
| Voltage | 220V AC or built-in lithium battery |
| External Dimensions (L × W × H) | 420 × 320 × 190 mm |
| Net Weight | ≤ 9 kg |
Description
Portable Ion Chromatograph – Quali-IC™ 80
The Quali-IC™ 80 Portable Ion Chromatograph is a compact, self-contained ion chromatography system built for field and on-site testing where full-scale laboratory instruments are not feasible. Designed for mobility without sacrificing performance, it integrates advanced analytical capability, rugged housing, and battery-powered functionality into one streamlined unit.
Equipped with conductivity detection, the system separates and measures anions and cations at trace levels, delivering dependable results across concentrations ranging from parts per billion (ppb) to parts per million (ppm). Metal-free PEEK flow paths help maintain chemical compatibility and sample integrity, while automatic signal range adjustment and stable pumping control ensure consistent, high-quality data. The Quali-IC™ 80 brings reliable, laboratory-level ion analysis directly to the point of sampling.
Portable Ion Chromatograph – Quali-IC™ 80 Applications
Environmental Monitoring
On-site measurement of anions and cations in surface water, groundwater, and wastewater, eliminating delays associated with sample transport to a central laboratory.
Drinking Water and Utilities
Rapid field verification of ionic contaminants and regulatory compliance parameters in municipal and potable water systems.
Industrial Process Monitoring
Real-time ion measurement in process fluids, cooling water systems, and chemical solutions to support quality control and operational efficiency.
Emergency and Mobile Laboratories
Portable ion chromatography for field investigations, spill response, environmental incidents, and mobile testing operations.
Research and Education
Practical ion chromatography analysis for academic instruction, demonstrations, and applied research where portability and straightforward operation are essential.
Standards
The following standards define the proper use of ion chromatography (IC) across multiple applications to ensure accurate results and regulatory compliance.
1. Water and Environmental Monitoring
General Anion Analysis (Water and Wastewater)
- ASTM D2036: Determination of common inorganic anions such as chloride, sulfate, and nitrate in water.
- ASTM D6832: Measurement of both anions and cations in water, particularly for industrial systems and power generation.
- ASTM D6919: Analysis of dissolved inorganic anions in water and wastewater.
- ASTM D7359: Measurement of trace-level anions in water using suppressed conductivity detection.
- ASTM D7994: Determination of inorganic anions using advanced ion chromatography techniques.
- US EPA 300.0 / 300.1: Measurement of inorganic anions, including fluoride, chloride, nitrate, nitrite, and sulfate, in drinking water and wastewater.
- US EPA 1636: Determination of inorganic anions in aqueous samples for environmental monitoring.
- DIN 38409-59 and EN 17813: European standards for measuring inorganic anions in water and wastewater.
Specialized Contaminants and Sample Types
- ASTM D5794: Measurement of inorganic anions in atmospheric deposition, including rain and snow.
Perchlorate Analysis (Environmental and Drinking Water):
- US EPA 302.0: Measurement of perchlorate in environmental water samples.
- US EPA 314.0: Detection of low-level perchlorate in drinking water.
- US EPA 332.0: Measurement of perchlorate in drinking water using suppressed conductivity detection.
Disinfection Byproducts:
- US EPA 321.8: Measurement of bromate, bromide, chlorite, and chlorate in drinking water.
Mixed Organic and Inorganic Analysis:
- US EPA 6860: Measurement of organic acids and inorganic anions in water samples.
Solid Waste and Soil Analysis
- US EPA 9056 / 9058: Determination of inorganic anions in soil, solid waste, and aqueous extracts.
2. Combustion Ion Chromatography (Petrochemicals and Materials)
- ASTM D8247: Determination of total fluorine, halogens, and sulfur in various materials using combustion ion chromatography.
- US EPA 1621: Measurement of adsorbable organic fluorine, chlorine, and bromine compounds.
- UOP 991: Determination of trace halogens and sulfur in petroleum products.
3. Food, Beverage, and Nutritional Analysis (AOAC)
General Food and Beverage Testing
- AOAC 995.13: Measurement of chloride, nitrate, and sulfate in food products.
- AOAC 996.04: Analysis of organic acids and inorganic ions in food and beverages.
- AOAC 997.08: Measurement of bromide and bromate in food and beverage samples.
- AOAC 2000.11: Determination of anions in dairy and processed food products.
Nutritional and Safety Analysis
- AOAC 2001.02: Measurement of nitrate and nitrite levels in food products.
- AOAC 2012.20: Determination of inorganic anions in infant formula and nutritional supplements.
4. Electronics and Industrial Compliance
- IEC 62321: Determination of halogen content in electrical and electronic products to support RoHS compliance.
- IPC-TM-650 2.3.28: Measurement of ionic contamination on printed circuit boards (PCBs).
These standards provide validated procedures for ion chromatography across environmental, industrial, food, pharmaceutical, and electronics applications, supporting reliable analysis and regulatory compliance.
Portable Ion Chromatograph – Quali-IC™ 80 Key Features
True Portable Ion Chromatograph Design
Compact, lightweight enclosure designed specifically for outdoor and on-site ion chromatography, allowing convenient transport and reliable operation in field environments.
Dual Power Operation
Supports both 220V AC power and an integrated lithium battery, ensuring continuous analysis whether operating in the laboratory or in remote locations.
Metal-Free Flow Path
Chemically inert PEEK flow system compatible with aqueous eluents across a pH range of 0–14, as well as reversed-phase solvents, helping maintain sample integrity and broad chemical compatibility.
Auto-Range Conductivity Detection
Automatically adjusts the detection range to support accurate ion measurement from parts per billion (ppb) to parts per million (ppm) concentrations.
Uninterruptible Power Supply (UPS)
Allows battery replacement without interrupting instrument operation, helping protect ongoing analysis and preserving data continuity.
Water–Electricity Separation Design
Separates fluid pathways from electrical components to reduce the risk of circuit damage caused by eluent leaks during field operation.
User-Friendly Operation
Includes a Bluetooth keyboard and mouse for convenient system control, simplifying setup and operation in both laboratory and field settings.
Portable Ion Chromatograph – Quali-IC™ 80 Technical Specifications
| Parameter | Specification |
|---|---|
| Instrument Type | Portable Ion Chromatograph |
| Pump Type | Dual-piston serial pump |
| Maximum Pump Pressure | 42 MPa |
| Flow Rate Range | 0.001 – 12 mL/min |
| Flow Stability | ≤ 0.67% |
| Flow Path Material | Metal-free PEEK |
| Supported Column Sizes | 2, 3, 4, and 5 mm I.D. |
| Maximum Column Length | 250 mm analytical + 50 mm guard |
| Suppressor Type | Self-regenerating electrolytic micro-membrane |
| Detection Method | Auto-range conductivity detector |
| Detector Cell Volume | ≤ 0.8 µL |
| Detection Range | 0 – 45,000 µS/cm |
| Resolution | ≤ 0.0020 nS/cm |
| Linearity | ≥ 0.999 |
| Quantitative Repeatability | ≤ 0.71% |
| Qualitative Repeatability | ≤ 0.07% |
| Minimum Detectable Concentration | Cl⁻ ≤ 0.0012 µg/mL; Li⁺ ≤ 0.0012 µg/mL |
| Column Heater Range | Ambient +5 °C to 60 °C |
| Temperature Accuracy | ±0.2 °C |
| Voltage | 220V AC or built-in lithium battery |
| External Dimensions (L × W × H) | 420 × 320 × 190 mm |
| Net Weight | ≤ 9 kg |